English
Language : 

SN74ALVC7805 Datasheet, PDF (9/14 Pages) Texas Instruments – 256 × 18 LOW-POWER CLOCKED FIRST-IN, FIRST-OUT MEMORY
SN74ALVC7805
256 × 18
LOW-POWER CLOCKED FIRST-IN, FIRST-OUT MEMORY
SCAS593A – OCTOBER 1997 – REVISED APRIL 1998
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V
Output voltage range, VO (see Notes 1 and 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Voltage range applied to a disabled 3-state output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 3.6 V
Input clamp current, IIK ( VI < 0 ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA
Output clamp current, IOK ( VO < 0 or VO > VCC ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO ( VO = 0 to VCC ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Package thermal impedance, θJA (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings can be exceeded if the input and output clamp current ratings are observed.
2. This value is limited to 4.6 V maximum.
3. The package thermal impedance is calculated in accordance with JESD 51.
recommended operating conditions
VCC
VIH
VIL
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
High-level output current, Q outputs, flags
Low-level output current, Q outputs, flags
Operating free-air temperature
VCC = 3 V
VCC = 3 V
’ALVC7805-20 ’ALVC7805-25 ’ALVC7805-40
MIN MAX MIN MAX MIN MAX
3 3.6
3 3.6
3 3.6
2
2
2
0.8
0.8
0.8
–8
–8
–8
16
16
16
0
70
0
70
0
70
UNIT
V
V
V
mA
mA
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP‡ MAX UNIT
VIK
VCC = 3 V,
IIK = –18 mA
–1.2 V
VOH Flags, Q outputs
VCC = 3 V to 3.6 V,
VCC = 3 V,
IOH = –100 µA
IOH = –8 mA
VCC–0.2
V
2.4
Flags, Q outputs VCC = 3 V to 3.6 V,
IOL = 100 µA
0.2
VOL Flags
VCC = 3 V,
IOL = 8 mA
0.4 V
Q outputs
VCC = 3 V,
IOL = 16 mA
0.55
II
VCC = 3.6 V,
VI = VCC or GND
±5 µA
IOZ
VCC = 3.6 V,
VO = VCC or GND
±10 µA
ICC
VI = VCC or 0
40 µA
∆ICC§
VCC = 3.6 V, Other inputs at VCC or GND, One input at VCC – 0.6 V
500 µA
Ci
VCC = 3.3 V,
VI = VCC or GND
2.5
pF
Co
VCC = 3.3 V,
VO = VCC or GND
5.5
pF
‡ All typical values are at VCC = 3.3 V, TA = 25°C.
§ This is the supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265