English
Language : 

MSP430X241X Datasheet, PDF (74/98 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430x241x, MSP430x261x
MIXED SIGNAL MICROCONTROLLER
SLAS541A -- JUNE 2007 -- REVISED OCTOBER 2007
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
flash memory
PARAMETER
TEST
CONDITIONS
VCC
MIN TYP MAX UNIT
VCC(PGM/ERASE)
fFTG
IPGM
IERASE
tCPT
tCMErase
tRetention
Program and erase supply voltage
Flash Timing Generator frequency
Supply current from DVCC during program
Supply current from DVCC during erase
Cumulative program time
Cumulative mass erase time
Program/Erase endurance
Data retention duration
See Note 1
See Note 2
TJ = 25°C
2.2
257
2.2 V/ 3.6 V
2.2 V/ 3.6 V
2.2 V/ 3.6 V
2.2 V/ 3.6 V 200
104
100
3.6 V
476 kHz
3
5 mA
3
7 mA
4 ms
ms
105
cycles
years
tWord
Word or byte program time
See Note 3
35
tFTG
tBlock, 0
Block program time for first byte or word
See Note 3
30
tFTG
tBlock, 1-63
Block program time for each additional byte or word See Note 3
21
tFTG
tBlock, End
Block program end-sequence wait time
See Note 3
6
tFTG
tMass Erase
Mass erase time (see Note 4)
See Note 3
10593
tFTG
tSeg Erase
Segment erase time
See Note 3
4819
tFTG
NOTES:
1. The cumulative program time must not be exceeded when writing to a 64-byte flash block. This parameter applies to all programming
methods: individual word/byte write and block write modes.
2. The mass erase duration generated by the flash timing generator is at least 11.1 ms ( = 5297x1/fFTG,max = 5297 × 1/476 kHz). To
achieve the required cumulative mass erase time, the Flash Controller’s mass erase operation can be repeated until this time is met.
A worst case minimum of 19 cycles is required.
3. These values are hardwired into the Flash Controller’s state machine (tFTG = 1/fFTG).
4. To erase the complete code area, the mass erase must be performed once with a dummy address in the range of the lower 64-kB
flash addresses and once with the dummy address in the upper 64-kB flash addresses.
RAM
PARAMETER
TEST CONDITIONS
MIN MAX UNIT
VRAMh See Note 1
CPU halted
1.6
V
NOTE 1: This parameter defines the minimum supply voltage when the data in program memory RAM remain unchanged. No program execution
should take place during this supply voltage condition.
74