English
Language : 

MSP430X241X Datasheet, PDF (32/98 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430x241x, MSP430x261x
MIXED SIGNAL MICROCONTROLLER
SLAS541A -- JUNE 2007 -- REVISED OCTOBER 2007
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
low-power mode supply current into VCC excluding external current (see Notes 1 and 2)
PARAMETER
ILPM0, 1MHz
Low-power mode 0
(LPM0) current,
see Note 3
TEST CONDITIONS
fMCLK = 0 MHz,
fSMCLK = fDCO = 1 MHz,
fACLK = 32,768 Hz,
BCSCTL1 = CALBC1_1MHZ,
DCOCTL = CALDCO_1MHZ,
CPUOFF = 1, SCG0 = 0, SCG1 = 0,
OSCOFF = 0
TA
--40_C to 85_C
105_C
VCC
2.2 V
--40_C to 85_C
3V
105_C
MIN TYP MAX UNIT
68
83
83
98
μA
87 105
100 125
ILPM0,
100kHz
ILPM2
Low-power mode 0
(LPM0) current,
see Note 3
Low-power mode 2
(LPM2) current,
see Note 4
fMCLK = 0MHz,
fSMCLK = fDCO(0, 0) ≈ 100 kHz,
fACLK = 0 Hz,
RSELx = 0, DCOx = 0,
CPUOFF = 1, SCG0 = 0, SCG1 = 0,
OSCOFF = 1
fMCLK = fSMCLK = 0 MHz, fDCO = 1 MHz,
fACLK = 32,768 Hz,
BCSCTL1 = CALBC1_1MHZ,
DCOCTL = CALDCO_1MHZ,
CPUOFF = 1, SCG0 = 0, SCG1 = 1,
OSCOFF = 0
--40_C to 85_C
105_C
--40_C to 85_C
105_C
--40_C to 85_C
105_C
--40_C to 85_C
105_C
--40°C
2.2 V
3V
2.2 V
3V
37
49
50
62
μA
40
55
57
73
23
33
35
46
μA
25
36
40
55
0.8 1.2
ILPM3,LFXT1
Low-power mode 3
(LPM3) current,
see Note 4
fDCO = fMCLK = fSMCLK = 0 MHz,
fACLK = 32,768 Hz,
CPUOFF = 1, SCG0 = 1, SCG1 = 1,
OSCOFF = 0
25°C
85°C
105°C
--40°C
25°C
85°C
2.2 V
3V
1 1.3
4.6
7
14
24
μA
0.9 1.3
1.1 1.5
5.5
8
105°C
17
30
--40°C
0.4 1.0
ILPM3,VLO
Low-power mode 3
(LPM3) current,
see Note 4
fDCO = fMCLK = fSMCLK = 0 MHz,
fACLK from internal LF oscillator (VLO),
CPUOFF = 1, SCG0 = 1, SCG1 = 1,
OSCOFF = 0
25°C
85°C
105°C
--40°C
25°C
85°C
2.2 V
3V
0.5 1.0
4.3 6.5
14
24
μA
0.6 1.2
0.6 1.2
5 7.5
105°C
16.5 29.5
NOTES:
1. All inputs are tied to 0 V or VCC. Outputs do not source or sink any current.
2. The currents are characterized with a micro crystal CC4V-T1A SMD crystal with a load capacitance of 9 pF. The internal and external
load capacitance is chosen to closely match the required 9 pF.
3. Current for Brownout and WDT+ is included. The WDT+ is clocked by SMCLK.
4. Current for Brownout and WDT+ is included. The WDT+ is clocked by ACLK.
32
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265