ELECTRICAL CHARACTERISTICS (continued)
5.0V ≤ V(VCC) ≤ 28V, 0°C < TJ < +125°C, typical values are at TA = 25°C, with respect to GND (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
BAT OVER-VOLTAGE COMPARATOR
VOV_RISE
Over-voltage rising threshold
VOV_FALL
Over-voltage falling threshold
INPUT OVER-VOLTAGE COMPARATOR (ACOV)
As percentage of VFB ,T1 – T5
As percentage of VFB,T1 – T5
104%
102%
VACOV
AC over-voltage rising threshold on
VCC
31.04
32 32.96
V
VACOV_HYS
AC over-voltage falling hysteresis
AC over-voltage deglitch (both edge)
Delay to changing the STAT pins
1
V
1
ms
AC over-voltage rising deglitch
Delay to turn-off ACFET, disable charge
1
ms
AC over-voltage falling deglitch
Delay to turn on ACFET, resume charge
20
ms
THERMAL SHUTDOWN COMPARATOR
TSHUT
TSHUT_HYS
Thermal shutdown rising temperature
Thermal shutdown hysteresis
Thermal shutdown rising deglitch
Temperature increasing
Temperature increasing
145
°C
15
°C
100
ms
Thermal shutdown falling deglitch
Temperature decreasing
10
ms
THERMISTOR COMPARATOR
VT1
T1 (0 °C) threshold, Charge suspended
below this temperature.
VTS rising, As Percentage to VVREF
70.2% 70.8% 71.4%
VT1-HYS
Charge back to ICHARGE/2 and VFB=2.1
V above this temperature.
Hysteresis, VTS falling
0.6%
T2 (10 °C) threshold, Charge back to
VT2
ICHARGE/2 and VFB=2.1 V below this
VTS rising, As Percentage to VVREF
temperature.
68.0% 68.6% 69.2%
VT2-HYS
Charge back to ICHARGE and VFB=2.1 V
above this temperature.
Hysteresis, VTS falling
0.8%
T3 (45 °C) threshold, Charge back to
VT3
ICHARGE and VFB=2.05 V above this
VTS falling, As Percentage to VVREF
temperature.
55.5% 56.1% 56.7%
VT3-HYS
Charge back to ICHARGE and VFB=2.1 V
below this temperature.
Hysteresis, VTS rising
0.8%
T4 (50 °C) threshold, Charge back to
VT4
ICHARGE and VFB=2.025 V above this
VTS falling, As Percentage to VVREF
temperature.
53.2% 53.7% 54.2%
VT4-HYS
Charge back to ICHARGE and VFB=2.05 V
below this temperature.
Hysteresis, VTS rising
0.8%
VT5
T5 (60 °C) threshold, Charge
suspended above this temperature.
VTS falling, As Percentage to VVREF
47.6% 48.1% 48.6%
VT5-HYS
Charge back to ICHARGE and VFB=2.025
V below this temperature.
Hysteresis, VTS rising
1.2%
Deglitch time for Temperature Out of
Valid Charge Range Detection
Deglitch time for Temperature In Valid
Range Detection
VTS < VT5 or VTS > VT1
VTS > VT5 + VT5_HYS or VTS < VT1 - VT1_HYS
400
ms
20
Deglitch time for Temperature Detection
above/below T2, T3, T4 threshold
25
ms
Charge Current when VTS between VT1
and VT2 range
CHARGE OVER-CURRENT COMPARATOR (CYCLE-BY-CYCLE)
ICHARGE
/2
Charge over-current falling threshold
Current rising, in non-synchronous mode, measure on
V(SRP-SRN), VSRP < 2 V
45.5
mV
Current rising, as percentage of V(IREG_CHG), in
VOC
Charge over-current threshold floor
synchronous mode, VSRP > 2.2V
Minimum OCP threshold in synchronous mode,
measure on V(SRP-SRN), VSRP > 2.2V
160%
50
mV
Charge over-current threshold ceiling
Maximum OCP threshold in synchronous mode,
measure on V(SRP-SRN), VSRP > 2.2V
180
mV
6