English
Language : 

MSP430X15X Datasheet, PDF (48/73 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430x15x, MSP430x16x, MSP430x161x
MIXED SIGNAL MICROCONTROLLER
SLAS368E − OCTOBER 2002 − REVISED AUGUST 2006
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted)
Flash Memory
PARAMETER
VCC(PGM/
ERASE)
Program and Erase supply voltage
TEST
CONDITIONS
VCC
MIN NOM MAX UNIT
2.7
3.6 V
fFTG
IPGM
IERASE
tCPT
tCMErase
Flash Timing Generator frequency
Supply current from DVCC during program
Supply current from DVCC during erase
Cumulative program time
Cumulative mass erase time
Program/Erase endurance
see Note 1
see Note 2
257
476 kHz
2.7 V/ 3.6 V
3
5 mA
2.7 V/ 3.6 V
3
7 mA
2.7 V/ 3.6 V
4 ms
2.7 V/ 3.6 V 200
104 105
ms
cycles
tRetention
Data retention duration
TJ = 25°C
100
years
tWord
Word or byte program time
35
tBlock, 0
Block program time for 1st byte or word
30
tBlock, 1-63
tBlock, End
Block program time for each additional byte or word
Block program end-sequence wait time
see Note 3
21
6
tFTG
tMass Erase
Mass erase time
5297
tSeg Erase
Segment erase time
4819
NOTES:
1. The cumulative program time must not be exceeded when writing to a 64-byte flash block. This parameter applies to all programming
methods: individual word/byte write and block write modes.
2. The mass erase duration generated by the flash timing generator is at least 11.1ms ( = 5297x1/fFTG,max = 5297x1/476kHz). To
achieve the required cumulative mass erase time the Flash Controller’s mass erase operation can be repeated until this time is met.
(A worst case minimum of 19 cycles are required).
3. These values are hardwired into the Flash Controller’s state machine (tFTG = 1/fFTG).
JTAG Interface
PARAMETER
TEST
CONDITIONS
VCC
fTCK
TCK input frequency
see Note 1
2.2 V
3V
RInternal
Internal pull-up resistance on TMS, TCK, TDI/TCLK see Note 2
2.2 V/ 3 V
NOTES: 1. fTCK may be restricted to meet the timing requirements of the module selected.
2. TMS, TDI/TCLK, and TCK pull-up resistors are implemented in all versions.
MIN NOM MAX UNIT
0
5 MHz
0
10 MHz
25
60
90 kΩ
JTAG Fuse (see Note 1)
PARAMETER
TEST
CONDITIONS
VCC
MIN NOM MAX UNIT
VCC(FB)
Supply voltage during fuse-blow condition
TA = 25°C
2.5
V
VFB
Voltage level on TDI/TCLK for fuse-blow: F versions
6
7V
IFB
Supply current into TDI/TCLK during fuse blow
100 mA
tFB
Time to blow fuse
1 ms
NOTES: 1. Once the fuse is blown, no further access to the MSP430 JTAG/Test and emulation features is possible. The JTAG block is switched
to bypass mode.
48
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265