English
Language : 

MSP430X15X Datasheet, PDF (27/73 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430x15x, MSP430x16x, MSP430x161x
MIXED SIGNAL MICROCONTROLLER
SLAS368E − OCTOBER 2002 − REVISED AUGUST 2006
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
SCHMITT-trigger inputs − Ports P1, P2, P3, P4, P5, P6; RST/NMI; JTAG: TCK, TMS, TDI/TCLK, TDO/TDI
PARAMETER
TEST CONDITIONS MIN TYP MAX UNIT
VIT+
Positive-going input threshold voltage
VIT−
Negative-going input threshold voltage
Vhys
Input voltage hysteresis (VIT+ − VIT−)
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
1.1
1.5
V
1.5
1.98
0.4
0.9
V
0.9
1.3
0.3
1.1
V
0.5
1
inputs Px.x, TAx, TBx
t(int)
t(cap)
PARAMETER
External interrupt timing
Timer_A, Timer_B capture
timing
TEST CONDITIONS
Port P1, P2: P1.x to P2.x, external trigger signal
for the interrupt flag, (see Note 1)
TA0, TA1, TA2
TB0, TB1, TB2, TB3, TB4, TB5, TB6
(see Note 2)
VCC
2.2 V
3V
2.2 V
3V
MIN TYP MAX UNIT
62
ns
50
62
ns
50
f(TAext)
f(TBext)
Timer_A, Timer_B clock
frequency externally applied
to pin
TACLK, TBCLK, INCLK: t(H) = t(L)
2.2 V
3V
8
MHz
10
f(TAint)
f(TBint)
NOTES:
Timer_A, Timer_B clock
frequency
SMCLK or ACLK signal selected
2.2 V
3V
8
MHz
10
1. The external signal sets the interrupt flag every time the minimum t(int) parameters are met. It may be set even with trigger signals
shorter than t(int).
2. Seven capture/compare registers in ’x16x/161x and three capture/compare registers in ’x15x.
leakage current − Ports P1, P2, P3, P4, P5 and P6 (see Note 1)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
Ilkg(Px.y)
Leakage
current
Port Px V(Px.y) (see Note 2)
VCC = 2.2 V/3 V
±50
NOTES: 1. The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
2. The port pin must be selected as input.
UNIT
nA
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
27