BQ34Z100 Datasheet, PDF (35/50 Pages) Texas Instruments – Wide Range Fuel Gauge with Impedance Track™ Technology
bq34z100
www.ti.com
NAME
AtRate()
AtRateTimeToEmpty()
NominalAvailableCapacity()
FullAvailableCapacity()
TimeToEmpty()
TimeToFull()
StandbyCurrent()
StandbyTimeToEmpty()
MaxLoadCurrent()
MaxLoadTimeToEmpty()
AvailableEnergy()
AveragePower()
TTEatConstantPower()
Internal_Temp()
CycleCount()
StateOfHealth()
ChargeVoltage()
ChargeCurrent()
PassedCharge()
DOD0()
SelfDischargeCurrent
PackConfiguration()
DesignCapacity()
DataFlashClass() (2)
DataFlashBlock() (2)
Authenticate()/BlockData()
AuthenticateCheckSum()/BlockData()
BlockData()
BlockDataCheckSum()
BlockDataControl()
DeviceNameLength()
DeviceName()
Reserved
Table 19. Extended Commands
AR
ARTTE
NAC
FAC
TTE
TTF
SI
STTE
MLI
MLTTE
AE
AP
TTECP
INTTEMP
CC
SOH
CHGV
CHGI
PCHG
DOD0
SDSG
PKCFG
DCAP
DFCLS
DFBLK
A/DF
ACKS/DFD
DFD
DFDCKS
DFDCNTL
DNAMELEN
DNAME
RSVD
COMMAND CODE
0X10 / 0x11
0x12 / 0x13
0x14 / 0x15
0x16 / 0x17
0x18 / 0x19
0x1a / 0x1b
0x1c / 0x1d
0x1e / 0x1f
0x20 / 0x21
0x22 / 0x23
0x24 / 0x25
0x26 / 0x27
0x28 / 0x29
0x2a / 0x2b
0x2c / 0x2d
0x2e/0x2f
0x30/0x31
0x32/0x33
0x34/0x35
0x36/0x37
0x38/0x39
0x3a / 0x3b
0x3c / 0x3d
0x3e
0x3f
0x40…0x53
0x54
0x55…0x5f
0x60
0x61
0x62
0x63...0x69
0x6a...0x7f
UNITS
mA
Minutes
mAh
mAh
Minutes
Minutes
mA
Minutes
mA
Minutes
10 mWhr
10 mW
Minutes
0.1°K
Counts
% / num
mV
mA
mAh
HEX#
mA
N/A
mAh
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SLUSAU1 – MAY 2012
SEALED
ACCESS (1), (2)
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
N/A
R/W
R/W
R/W
R
R/W
N/A
R
R
R
UNSEALED
ACCESS (1), (2)
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
AtRate(): 0X10/0x11
The AtRate() read-/write-word function is the first half of a two-function call-set used to set the AtRate value used
in calculations made by the AtRateTimeToEmpty() function. The AtRate() units are in mA.
The AtRate() value is a signed integer and both positive and negative values will be interpreted as a discharge
current value. The AtRateTimeToEmpty() function returns the predicted operating time at the AtRate value of
discharge. The default value for AtRate() is zero and will force AtRate() to return 65535.
AtRateTimeToEmpty(): 0x12/0x13
This read-word function returns an unsigned integer value of the predicted remaining operating time if the battery
is discharged at the AtRate() value in minutes with a range of 0 to 65534. A value of 65535 indicates
AtRate() = 0.
The gas gauge updates AtRateTimeToEmpty() within 1s after the host sets the AtRate() value. The gas gauge
automatically updates AtRateTimeToEmpty() based on the AtRate() value every 1 s.
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): bq34z100
Submit Documentation Feedback
35