BQ34Z100 Datasheet, PDF (34/50 Pages) Texas Instruments – Wide Range Fuel Gauge with Impedance Track™ Technology
bq34z100
SLUSAU1 – MAY 2012
REFERENCE
www.ti.com
OPERATION CONFIGURATION B REGISTER
Some bq34z100 advanced features are rarely used. Operation Configuration registers B and C are available for
configuring special applications. Default settings are recommended.
Bit 7
ChgDoDEoC
Bit 6
SE_TDD
Table 17. Operation Configuration B Bit Definition
Bit 5
VconsEN
Bit 4
SE_ISD
Bit 3
RSVD
Bit 2
LFPRelax
Bit 1
DoDWT
Bit 0
FConvEn
ChgDoDEoC: Enable DoD at EoC during charging only. True when set. Default is 1. Default setting is
recommended.
SE_TDD: Enable Tab Disconnection Detection. True when set. Default is 1.
VconsEN: Enable voltage consistency check. True when set. Default is 1. Default setting is
recommended.
SE_ISD: Enable Internal Short Detection. True when set. Default is 1.
RSVD: Reserved. Default is 1.
LFPRelax: Enable LiFePO4 long relaxation mode when chemical ID 400 series is selected. True
when set. Default is 1.
DoDWT: Enable Dod weighting for LiFePO4 support when chemical ID 400 series is selected.
True when set. Default is 1.
FConvEn: Enable fast convergence algorithm. Default is 1. Default setting is recommended.
OPERATION CONFIGURATION C REGISTER
Bit 7
FastQmax
Bit 6
RsvdSBS
Table 18. Operation Configuration C Bit Definition
Bit 5
Bit 4
FF_Near_End SleepWakeChg
Bit 3
RSVD
Bit 2
RSVD
Bit 1
RSVD
Bit 0
RSVD
FastQmax: Enable Fast Qmax Update mode. True when set. Default is 0. Default setting is
recommended.
RsvdSBS: Enable to activate debug information in command space 0x6d ~ 0x76. For special use
only. Default setting is recommended.
FF_Near_End: Enable to use a fast voltage filter near the end of discharge only. Default setting is
recommended.
SleepWakeChg: Enable for faster sampling in sleep mode. Default setting is recommended.
RSVD: Reserved. Default is 0.
EXTENDED DATA COMMANDS
Extended commands offer additional functionality beyond the standard set of commands. They are used in the
same manner; however unlike standard commands, extended commands are not limited to 2-byte words. The
number of command bytes for a given extended command ranges in size from single to multiple bytes, as
specified in Table 19. For details on the SEALED and UNSEALED states, refer to the section entitled Access
Modes.