English
Language : 

THS10082 Datasheet, PDF (22/37 Pages) Texas Instruments – 10 bit TWO ANALOG INPUT, 8 MSPS SIMULTANEOUS SAMPLING ANALOG TO DIGITAL CONVERTER
THS10082
SLAS254B – MAY 2002 – REVISED NOVEMBER 2002
www.ti.com
INITIALIZATION OF THE THS10082
The initialization of the THS10082 should be done according to the configuration flow shown in Figure 34.
Start
Use Default
No
Values?
Yes
Write 0x401 to
THS10082
(Set Reset Bit in CR1)
Write 0x401 to
THS10082
(Set Reset Bit in CR1)
Clear RESET By
Writing 0x400 to
CR1
Clear RESET By
Writing 0x400 to
CR1
Write The User
Configuration to
CR0
Write The User
Configuration to
CR1 (Can Include
FIFO Reset, Must
Exclude RESET)
Continue
Figure 34. THS10082 Configuration Flow
22