THS12082 Datasheet, PDF (21/38 Pages) Texas Instruments – 12-BIT, 8 MSPS, SIMULTANEOUS SAMPLING ANALOG-TO-DIGITAL CONVERTERS
THS12082
12-BIT, 8 MSPS, SIMULTANEOUS SAMPLING ANALOG-TO-DIGITAL CONVERTERS
SLAS271 – MAY 2000
DATA_AV type
Bit 4 and bit 5 (DATA_T, DATA_P) of control register 1 are used to program the signal DATA_AV. Bit 4 of
control register 1 determines whether the DATA_AV signal is static or a pulse. Bit 5 of the control register
determines the polarity of DATA_AV. This is shown in Table 14.
Table 14. DATA_AV Type
BIT 5
DATA_P
0
0
1
1
BIT 4
DATA_T
0
1
0
1
DATA_AV TYPE
Active low level
Active low pulse
Active high level
Active high pulse
The signal DATA_AV is set to active when the trigger condition is satisfied. It is set back inactive independent
of the DATA_T selection (pulse or level).
If level mode is chosen, DATA_AV is set inactive after the first of the TL (TL = trigger level) reads (with the falling
edge of READ). The trigger condition is checked again after TL reads.
If pulse mode is chosen, the signal DATA_AV is a pulse with a width of one half of a CONV_CLK cycle in
continuous conversion mode and one half of a clock cycle of the internal oscillator in single conversion mode.
When the TL values previously written into the FIFO were read out by the processor, the next DATA_AV pulse
(when the trigger condition is satisfied) is sent out first.