English
Language : 

MSP430FE42X2 Datasheet, PDF (19/48 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430FE42x2
MIXED SIGNAL MICROCONTROLLER
SLAS616 − JULY 2008
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
Schmitt-trigger inputs − Ports P1 and P2, RST/NMI, JTAG: TCK, TMS, TDI/TCLK, TDO/TDI
PARAMETER
TEST CONDITIONS MIN
VIT+
Positive-going input threshold voltage
VIT−
Negative-going input threshold voltage
Vhys
Input voltage hysteresis (VIT+ − VIT−)
VCC = 3 V
VCC = 3 V
VCC = 3 V
1.5
0.9
0.45
MAX
1.98
1.3
1
UNIT
V
V
V
inputs − Px.x, TAx
PARAMETER
t(int)
External interrupt timing
t(cap)
f(TAext)
Timer_A, capture timing
Timer_A clock frequency externally
applied to pin
TEST CONDITIONS
VCC
Port P1, P2: P1.x to P2.x, External trigger signal
3V
for the interrupt flag (see Note 1)
3V
TAx
3V
TACLK, INCLK t(H) = t(L)
3V
MIN MAX UNIT
1.5
cycle
50
ns
50
ns
10 MHz
f(TAint)
NOTES:
Timer_A clock frequency
SMCLK or ACLK signal selected
3V
10 MHz
1. The external signal sets the interrupt flag every time the minimum t(int) cycle and time parameters are met. It may be set even with
trigger signals shorter than t(int). Both the cycle and timing specifications must be met to ensure the flag is set. t(int) is measured in
MCLK cycles.
leakage current (see Note 1)
PARAMETER
TEST CONDITIONS
MIN MAX
Ilkg(P1.x)
Leakage current
Port P1 Port 1: V(P1.x) (see Note 2)
VCC = 3 V
±50
Ilkg(P2.x)
Port P2 Port 2: V(P2.x) (see Note 2)
VCC = 3 V
±50
NOTES: 1. The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
2. The port pin must be selected as an input.
UNIT
nA
nA
outputs − Ports P1 and P2
PARAMETER
TEST CONDITIONS
MIN
MAX
VOH High-level output voltage
IOH(max) = −1.5 mA, VCC = 3 V,
See Note 1 VCC−0.25
VCC
IOH(max) = −6 mA,
VCC = 3 V,
See Note 2
VCC−0.6
VCC
VOL Low-level output voltage
IOL(max) = 1.5 mA,
IOL(max) = 6 mA,
VCC = 3 V,
VCC = 3 V,
See Note 1
See Note 2
VSS VSS+0.25
VSS VSS+0.6
NOTES: 1. The maximum total current, IOH(max) and IOL(max), for all outputs combined, should not exceed ±12 mA to satisfy the
maximum specified voltage drop.
2. The maximum total current, IOH(max) and IOL(max), for all outputs combined, should not exceed ±48 mA to satisfy the
maximum specified voltage drop.
UNIT
V
V
output frequency
PARAMETER
fPx.y
fACLK,
fMCLK,
fSMCLK
(1 ≤ x ≤ 2, 0 ≤ y ≤ 7)
P1.1/TA0/MCLK,
P1.5/TACLK/ACLK/S28
tXdc
Duty cycle of output frequency
CL = 20 pF,
IL = ± 1.5mA
TEST CONDITIONS
VCC = 3 V
CL = 20 pF
VCC = 3 V
P1.5/TACLK/ACLK/S28,
CL = 20 pF
VCC = 3 V
P1.1/TA0/MCLK,
CL = 20 pF,
VCC = 3 V
fACLK = fLFXT1 = fXT1
fACLK = fLFXT1 = fLF
fACLK = fLFXT1
fMCLK = fDCOCLK
MIN TYP
dc
MAX UNIT
12 MHz
12 MHz
40%
30%
50% −
15 ns
50%
50%
60%
70%
50% +
15 ns
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
19