English
Language : 

MSP430FE42X2 Datasheet, PDF (13/48 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430FE42x2
MIXED SIGNAL MICROCONTROLLER
SLAS616 − JULY 2008
watchdog timer (WDT+)
The primary function of the WDT+ module is to perform a controlled system restart after a software problem
occurs. If the selected time interval expires, a system reset is generated. If the watchdog function is not needed
in an application, the module can be configured as an interval timer and can generate interrupts at selected time
intervals.
Timer_A3
Timer_A3 is a 16-bit timer/counter with three capture/compare registers. Timer_A3 can support multiple
capture/compares, PWM outputs, and interval timing. Timer_A3 also has extensive interrupt capabilities.
Interrupts may be generated from the counter on overflow conditions and from each of the capture/compare
registers.
INPUT PIN
NUMBER
48 - P1.5
48 - P1.5
53 - P1.0
52 - P1.1
51 - P1.2
51 - P1.2
45 - P2.0
DEVICE INPUT
SIGNAL
TACLK
ACLK
SMCLK
TACLK
TA0
TA0
DVSS
DVCC
TA1
TA1
DVSS
DVCC
TA2
ACLK (internal)
DVSS
DVCC
TIMER_A3 SIGNAL CONNECTIONS
MODULE INPUT
NAME
MODULE BLOCK
TACLK
ACLK
SMCLK
Timer
INCLK
CCI0A
CCI0B
GND
CCR0
VCC
CCI1A
CCI1B
GND
CCR1
VCC
CCI2A
CCI2B
GND
CCR2
VCC
MODULE OUTPUT
SIGNAL
NA
TA0
TA1
TA2
OUTPUT PIN
NUMBER
53 - P1.0
51 - P1.2
45 - P2.0
universal synchronous/asynchronous receive transmit (USART0)
The MSP430FE42x2 devices have one hardware USART0 peripheral module that is used for serial data
communication. The USART supports synchronous SPI (3-pin or 4-pin) and asynchronous UART
communication protocols, using double-buffered transmit and receive channels.
ESP430CE1B
The ESP430CE1B module integrates a hardware multiplier, two independent 16-bit sigma-delta A/D converters
(SD16) and an embedded signal processor (ESP430). The ESP430CE1B module measures 2 or 3-wire,
single-phase energy and automatically calculates parameters which are made available to the MSP430 CPU.
The module can be calibrated and initialized to accurately calculate energy, power factor, etc., for a wide range
of metering sensor configurations.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
13