English
Language : 

DRV8824-Q1_15 Datasheet, PDF (19/30 Pages) Texas Instruments – DRV8824-Q1 Automotive Motor Controller IC
www.ti.com
DRV8824-Q1
SLVSCH0 – APRIL 2014
9.2.2 Detailed Design Procedure
9.2.2.1 Stepper Motor Speed
The first step in configuring the DRV8824-Q1 requires the desired motor speed and microstepping level. If the
target application requires a constant speed, then a square wave with frequency fstep must be applied to the
STEP pin.
If the target motor speed is too high, the motor will not spin. Make sure that the motor can support the target
speed.
For a desired motor speed (v), microstepping level (nm), and motor full step angle (θstep),
fstep(step/sec)
=
v¾ (rpm)· nm(steps)· 6
qstep(°/step)
(3)
θstep can be found in the stepper motor datasheet or written on the motor itself.
For the DRV8824-Q1, the microstepping level is set by the USM pins and can be any of the settings in . Higher
microstepping will mean a smother motor motion and less audible noise, but will increase switching losses and
require a higher fstep to achieve the same motor speed.
9.2.2.2 Current Regulation
In a stepper motor, the full-scale current (IFS) is the maximum current driven through either winding. This quantity
will depend on the VREF analog voltage and the sense resistor value (RSENSE). During stepping, IFS defines the
current chopping threshold (ITRIP) for the maximum current step.
IFS(A) = A¾ vV·RRESEFNS(EV(W) ) = 5¾ V· RRESENFSE((VW))
(4)
IFS is set by a comparator which compares the voltage across RSENSE to a reference voltage. There is a current
sense amplifier built in with programmable gain through ISGAIN. Note that IFS must also follow the equation
below in order to avoid saturating the motor. VM is the motor supply voltage and RL is the motor winding
resistance.
IFS(A) < RL¾ (W) + 2 · RDSV(OMN)((WV)) + RSENSE(W)
(5)
9.2.2.3 Decay Modes
The DRV8824-Q1 supports three different decay modes: slow decay, fast decay, and mixed decay. The current
through the motor windings is regulated using a fixed-frequency PWM scheme. This means that after any drive
phase, when a motor winding current has hit the current chopping threshold (ITRIP), the DRV8824-Q1 will place
the winding in one of the three decay modes until the PWM cycle has expired. Afterwards, a new drive phase
starts.
The blanking time tBLANK defines the minimum drive time for the current chopping. ITRIP is ignored during tBLANK,
so the winding current may overshoot the trip level.
Copyright © 2014, Texas Instruments Incorporated
Submit Documentation Feedback
19