English
Language : 

TCA6408_09 Datasheet, PDF (13/31 Pages) Texas Instruments – LOW-VOLTAGE 8-BIT I2C AND SMBus I/O EXPANDER WITH INTERRUPT OUTPUT, RESET, AND CONFIGURATION REGISTERS
www.ti.com
TCA6408
LOW-VOLTAGE 8-BIT I2C AND SMBus I/O EXPANDER
WITH INTERRUPT OUTPUT, RESET, AND CONFIGURATION REGISTERS
SCPS151C – FEBRUARY 2007 – REVISED JUNE 2007
Electrical Characteristics
over recommended operating free-air temperature range, VCCI = 1.65 V to 5.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VCCP
MIN TYP(1)
VIK
Input diode clamp voltage II = –18 mA
1.65 V to 5.5 V
–1.2
VPOR
Power-on reset voltage(2) VI = VCCP or GND, IO = 0
1.65 V to 5.5 V
1
1.65 V
1.2
MAX
1.4
UNIT
V
V
IOH = –8 mA
2.3 V
1.8
3V
2.6
VOH
P port high-level output
voltage
4.5 V
4.1
V
1.65 V
1.1
IOH = –10 mA
2.3 V
1.7
3V
2.5
4.5 V
4.0
1.65 V
0.45
IOL = 8 mA
2.3 V
3V
0.25
0.25
VOL
P port low-level output
voltage
4.5 V
1.65 V
0.2
V
0.6
IOL = 10 mA
2.3 V
3V
0.3
0.25
4.5 V
0.2
IOL
II
IIH
IIL
ICC
(ICCI + ICCP)
∆ICCI
∆ ICCP
SDA
INT
SCL, SDA
ADDR, RESET
P port
P port
Operating
mode
SDA,
P Port,
ADDR,
RESET
Operating
mode
SDA,
P Port,
ADDR,
RESET
Standby
mode
SCL, SDA,
P Port,
ADDR,
RESET
Additional
current in
Standby
mode
SCL, SDA
P Port,
ADDR,
RESET
VOL = 0.4 V
VOL = 0.4 V
VI = VCCI or GND
VI = VCCP or GND
VI = VCCP
VI = GND
VI on SDA = VCCI or GND,
VI on P port, ADDR and
RESET = VCCP or GND,
IO = 0, I/O = inputs,
fSCL = 400 kHz
VI on SDA = VCCI or GND,
VI on P port, ADDR and
RESET = VCCP or GND,
IO = 0, I/O = inputs,
fSCL = 100 kHz
VI on SCL and SDA = VCCI or
GND,
VI on P Port, ADDR and
RESET = VCCP or GND,
IO = 0, I/O = inputs,
fSCL = 0
One input at VCCI – 0.6 V,
Other inputs at VCCI or GND
One input at VCCP – 0.6 V,
Other inputs at VCCP or GND
1.65 V to 5.5 V
1.65 V to 5.5 V
1.65 V to 5.5 V
1.65 V to 5.5 V
3.6 V to 5.5 V
2.3 V to 3.6 V
1.65 V to 2.3 V
3.6 V to 5.5 V
2.3 V to 3.6 V
1.65 V to 2.3 V
3.6 V to 5.5 V
2.3 V to 3.6 V
1.65 V to 2.3 V
1.65 V to 5.5 V
1.65 V to 5.5 V
3
3
15
10
6.5
4
2.5
1.6
1
0.2
0.1
0.1
mA
±0.1
µA
±0.1
1 µA
1 µA
20
15
9
5
3.8
µA
2.3
1
0.6
0.4
25 µA
60 µA
Ci
SCL
SDA
Cio
P Port
VI = VCCI or GND
VIO = VCCI or GND
VIO = VCCP or GND
1.65 V to 5.5 V
1.65 V to 5.5 V
6
7 pF
7
8
pF
7.5
8.5
(1) All typical values are at nominal supply voltage (1.8-V, 2.5-V, 3.3-V, or 5-V VCC) and TA = 25°C.
(2) When power (from 0 V) is applied to VCCP, an internal power-on reset holds the TCA6408 in a reset condition until VCCP has reached
VPOR. At that time, the reset condition is released, and the TCA6408 registers and I2C/SMBus state machine initialize to their default
states. After that, VCCP must be lowered to below 0.2 V and back up to the operating voltage for a power-reset cycle.
Submit Documentation Feedback
13