108-1228 Datasheet, PDF (5/7 Pages) TE Connectivity Ltd – Signal application only, 1 ampere maximum at 50% energized, See Figure 2.
4.
QUALITY ASSURANCE PROVISIONS
108-1228
4.1. Qualification Testing
A. Sample Selection
Sam ples shall be prepared in accordance with applicable Instruction Sheets and shall be selected
at random from current production. All test groups shall consist of number of samples specified in
Figure 4. All connectors shall have gold on contact interface. Backshells where required shall be
straight exit. Cable shall be 28 AW G (7/32) tin plated copper wire in accordance with Application
Specification 114-40029. 30 random contacts shall be selected and identified, contact selection
shall include ends of the connector. Unless otherwise specified, these contacts shall be used for all
m easurem ents.
Test Group Qty Position
Male
F em ale
Hardwar
e
Cable
Cable plug
Shielded round
5 120
Boardmount Latches
with backshell
jacketed
1
Cable plug
Shielded round
5 120
Panel mount Latches
with backshell
jacketed/ribbon
5 20 All plastic plug Boardmount None
Ribbon
5 50 All plastic plug Boardmount None
Ribbon
2
Cable plug
Shield round
5 50
Panel mount Latches
with backshell
jacketed/ribbon
5 50 All plastic plug Boardmount None
Ribbon
3
Cable plug
Shielded round
5 50
Panel mount Latches
with backshell
jacketed/ribbon
Cable plug Boardmount,
5 50
Latches
with backshell w/o board
None
4
Cable plug
5 50
Panel mount Latches
with backshell
None
Figure 4
B. Test Sequence
Qualification inspection shall be verified by testing samples as specified in Figure 3.
4.2. Requalification Testing
If changes significantly affecting form , fit or function are made to the product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
4.3. Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. W hen
product failure occurs, corrective action shall be taken and samples resubmitted for qualification.
Testing to confirm corrective action is required before resubm ittal.
Rev F
5 of 7