108-1228 Datasheet, PDF (4/7 Pages) TE Connectivity Ltd – Signal application only, 1 ampere maximum at 50% energized, See Figure 2.
108-1228
RECEPTACLE
# Denotes energized circuit
Figure 2
Current Energizing Circuit
3.6. Product Qualification and Requalification Test Sequence
Test or Exam ination
Examination of product
Termination resistance
Insulation resistance
Dielectric withstanding voltage
Capacitance
Vibration
Physical shock
Durability
Mating force
Unmating force
Housing lock strength
Thermal shock
Humidity-temperature cycling
Temperature life
Mixed flowing gas
Test Group (a)
1 2 3 4(c)
Test Sequence (b)
1,9 1,5 1,5 1,9
3,7 2,4 2,4
3,7
4,8
2
5
6
4
2
8
10
5
6
3
3(d)
NOTE (a) See paragraph 4.1.A.
(b) Numbers indicate sequence in which tests are performed.
(c) No wires or printed circuit boards used with test sequence 4.
(d) Precondition samples with 10 cycles durability.
Figure 3
Rev F
4 of 7