DC and AC parameters
6
DC and AC parameters
STCD1020, STCD1030, STCD1040
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow are derived from tests performed under the measurement conditions summarized in
Table 6. Designers should check that the operating conditions in their circuit match the
operating conditions when relying on the quoted parameters.
Table 6. Operating and AC measurement conditions (1.8 V supply)
Parameter
Condition
Unit
VCC supply
Output clock voltage (CLK1…CLK4)
Device enable voltage (EN1…EN4)
Ambient operating temperature (TA)
1.65 to 2.75
V
0 to VCC
V
0 to VCC
V
–40 to +85
°C
Table 7. DC and AC characteristics (1.8 V supply)
Symbol
Parameter
Condition(1)
Min
fMCLK
VCC
Vin
Vout
Master clock (eg. from VCTCXO)
Supply voltage
Input clock voltage level(2)
Output gain level(3)
IQ Quiescent current(4)
IACT Active current(5)
Sine wave/square wave
10
1.65
0.75
CL = 10 pF
–1.5
2 buffers version
3 buffers version
4 buffers version
1 channel enabled
2 channels enabled
3 channels enabled
ISB Standby current
RIN Input resistance
CIN Input capacitance
tr/f Rise/fall time(6)
BW Signal bandwidth(3)
VENH
VENL
Enable voltage high(7)
Enable voltage low(7)
4 channels enabled
All buffers disabled
At DC level
f = 26 MHz
Vin = 1 Vpp, CL = 10 pF
Square wave input/output
Vin = 1 Vpp, –1 dB, CL = 10 pF
Sine wave input/output
EN1~EN4
1.2
EN1~EN4
Typ
26
1.8
1
–0.5
1.6
2.0
2.6
1.7
2.2
2.7
3.2
>100
3
2
52
Max Unit
52 MHz
2.75 V
Vpp
dB
2.6
3.3 mA
4
mA
1
μA
kΩ
4
pF
5
ns
MHz
V
0.6 V
16/40
Doc ID 13823 Rev 6