English
Language : 

SKY66100_11 Datasheet, PDF (5/16 Pages) Skyworks Solutions Inc. – 169 to 170 MHz Transmit-Receive Front-End Module
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Table 6. SKY66100-11 Transmit Mode Electrical Specifications (Note 1) (Note 2)
(VCC = +3.3 V, TC = +25 C, f = 169 to 170 MHz, Characteristic Source and Load Impedance = 50 Ω, with Output Matching Network as in
Figure 3, CW Input, Unless Otherwise Noted)
Parameter
Symbol
Transmit Mode: TX to PA_OUT  TX_IN to ANT Path (Note 3)
Test Condition
Min
Typical
Max
Units
Output power
PA power added efficiency (Note 7)
2nd harmonic (Note 6 and Note 8)
3rd to 10th harmonics (Note 6 and Note 8)
Input return loss (Note 6 and Note 9)
Output return loss (Note 3 and Note 6)
Non-harmonic spurious power
(Note 6, Note 8, and Note 10)
Power-on time (Note 6 and Note 11)
Receive isolation (Note 13)
POUT
PAE_PA
2fo
3fo
4fo
5fo
6fo
7fo
8fo
9fo
10fo
|S11|
|S22|
TON_TX
|SRXTX|
VCC = 3.6 V (Note 4)
VCC = 3.3 V (Note 5 and Note 6)
At PA_OUT pin (Note 4)
At PA_OUT pin (Note 5 and Note 6)
PIN = –30 dBm
8
PIN = –30 dBm
6
VSWR = 5:1, all phases
Final mode = transmit (see Table 8)
+27
dBm
+24
dBm
45
%
55.8
%
–36
dBm
–54
dBm
–54
dBm
–54
dBm
–54
dBm
–54
dBm
–54
dBm
–54
dBm
–54
dBm
dB
dB
–40
dBm
2.8
μs
12
dB
Transmit Bypass Mode: TX to ANT Path
Insertion loss (Note 12)
IL
VCC = 3.0 to 3.6 V
0.9
dB
1 dB input compression point (Note 6)
IP1dB
21
dBm
2nd harmonic (Note 6 and Note 8)
2fo
PIN_TX = +20 dBm
–36
dBm
3rd to 5th harmonics (Note 6 and Note 8)
3fo-5fo
PIN_TX = +20 dBm
–54
dBm
Input return loss (Note 6 and Note 9)
|S11|
6
dB
Output return loss (Note 3 and Note 6)
|S22|
8
dB
Transition time (Note 6 and Note 11)
tON
Final mode = transmit bypass (see
Table 8)
1
μs
Receive isolation
|SRXTX|
PIN_TX = +20 dBm
25
dB
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Mode configured according to logic shown in Table 8.
Note 3: External output matching network and filter located between PA_OUT and TX_IN (pins 13 and 10, respectively).
Note 4: Requires EK2 output match network designed for +27 dBm. See Figure 4. Contact Skyworks Application Support for more information.
Note 5: Requires EK1 output match network designed for +24 dBm. See Figure 3. Contact Skyworks Application Support for more information.
Note 6: Not production tested.
Note 7: Calculated from Evaluation Board test results with loss of output matching network.
Note 8: Final performance dependent on external filter. The 2nd to 10th harmonics are fully characterized but are not production tested.
Note 9: External input matching network.
Note 10: Measurement performed with spectrum analyzer (RBW = 100 kHz for frequencies < 1 GHz and RBW = 1 MHz for frequencies between 1 GHz and 10 GHz).
Note 11: Elapsed time is from sleep mode to the final mode indicated in Table 8. A final mode is considered achieved when its corresponding POUT is at least 90% of its final value.
Note 12: The insertion loss increases to 2 dB in TX bypass mode with the external input match. The RX bypass is not affected.
Note 13: Includes gain of PA.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
5