English
Language : 

SKY66100_11 Datasheet, PDF (4/16 Pages) Skyworks Solutions Inc. – 169 to 170 MHz Transmit-Receive Front-End Module
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Table 4. SKY66100-11 DC Electrical Specifications (Note 1)
(VCC = +3.3 V, TC = +25 C, with Output Matching Network as Noted, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Receive quiescent current
(Pins: VCC0, VCC1, VCC2)
IQ_RX
Rx mode (Note 2)
Transmit quiescent current
(Pins : VCC0, VCC1, VCC2)
IQ_TX
Tx mode
Transmit bypass quiescent current
(Pins: VCC0, VCC1, VCC2)
IQ_TXBYP
Tx bypass mode (Note 2)
Transmit operating current
(Pins: VCC0, VCC1, VCC2)
IOP_TX
TX mode:
VCC = 3.3 V, POUT = +24 dBm
(Note 3 and Note 5)
VCC = 3.6 V, POUT = +27 dBm (Note 4)
Shutdown current (Pins: VCC0, VCC1, VCC2) ISD
(Note 5, Note 6, and Note 7)
Shutdown/sleep mode
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Does not include control pin currents. See Table 7 for more information.
Note 3: Requires EK1 output match network designed for +24 dBm. See Figure 3. Contact Skyworks Application Support for more information.
Note 4: Requires EK2 output match network designed for +27 dBm. See Figure 4. Contact Skyworks Application Support for more information.
Note 5. Not production tested.
Note 6: Shutdown mode functionally verified in production to be less than 1 mA.
Note 7: All controls must be <0.1 V to achieve the specified sleep current.
Typical
680
15
680
210
325
0.02
Max
Units
μA
mA
μA
mA
mA
1.0
μA
Table 5. SKY66100-11 Receive Mode Electrical Specifications (Note 1)
(VCC = +3.3 V, TC = +25 C, f = 169 to 170 MHz, Characteristic Source and Load Impedance = 50 Ω, CW Input, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Receive Mode: ANT to RX Output Path (Note 2)
Insertion loss (Note 3)
1 dB input compression point (Note 4)
3rd order input intercept point (Note 4)
IL
IP1dB
IIP3
0.4
dB
+15
dBm
+29
dBm
Input return loss (Note 4)
|S11|
8
dB
Power-on time, RX (Note 4 and Note 5)
TON_RX
Final mode = RX (see Table 8)
1
μs
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Mode configured according to logic shown in Table 8.
Note 3: Insertion loss increases to 0.9 dB when using an external antenna filter. See Figure 3.
Note 4: Not production tested.
Note 5: Elapsed time is from sleep mode to the final mode indicated in Table 8. A final mode is considered achieved when its corresponding POUT is at least 90% of its final value.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E