Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY85806-11 are
provided in Table 2. The recommended operating conditions are
specified in Table 3. The electrical specifications are provided in
Tables 4 through 13. The state of the SKY85806-11 is
determined by the logic provided in Table 14.
The typical performance characteristics of the SKY85806-11
are illustrated in Figures 3 and 4.
Table 2. SKY85806-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum Maximum
Units
Supply voltage
VCC
–0.3
3.6
V
PA enable pins: ENa, ENg
PU
–0.3
3.6
V
Maximum power input to TXa, TXg, with ANT terminated in 10:1 load or better TXRF
12.0
dBm
Operating temperature
TA
–40
+85
°C
Storage temperature
TSTG
–40
+150
°C
Electrostatic discharge:
ESD
Human Body Model (HBM), Class 1C (ANT pin zap to ground)
Human Body Model (HBM), Class 1C (all remaining pins)
1.5
kV
1
kV
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY85806-11 Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply voltage
VCC
3.0
3.3
3.6
V
Ground pad temperature
TA
–40
+25
+85
°C
Table 4. SKY85806-11 Electrical Specifications: DC Characteristics (Note 1)
(VCC = 3.3 V, TA = 25 C as Measured on the Evaluation Board, All Unused Ports are Terminated with 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Minimum Typical Maximum Units
Total transmit supply current:
802.11a
802.11g
802.11g
802.11b
802.11a/n
802.11ac – 2G
802.11ac – 5G
ICQ-A
ICQ-G
ICC-G
ICC-B
ICC-A
ICC-AC2G
ICC-AC5G
Control state 9 or 18, no RF
Control state 4, no RF
Control state 4, POUT = +18 dBm, 54 Mbps OFDM signal, 64 QAM
Control state 4, POUT = +21 dBm, 11 Mbps CCK signal, BT = 0.45
Control state 9 or 18, POUT = +16.5 dBm, MCS7, 40 MHz
Control state 4, POUT = +17 dBm, 256 QAM, MCS9, 40 MHz
Control state 9, POUT = +15 dBm, 256 QAM, MCS9, 80 MHz
175
185
mA
145
160
mA
220
245
mA
275
300
mA
230
245
mA
200
225
mA
215
230
mA
Total receive supply current:
2G
5G
ICC-RX2
ICC-RX5
Control state 1
Control states 6 or 15
13.5
mA
14
mA
Total supply current
IBYPASS
IBTREADY
ISLEEP
Control state 2, 3, 7, 8
Control state 20
Control state 21
12
μA
12
μA
1
μA
Note 1: Performance is guaranteed only under the conditions listed in this table.