English
Language : 

SP6120B Datasheet, PDF (3/22 Pages) Sipex Corporation – Low Voltage, AnyFETTM, Synchronous ,Buck Controller Ideal for 2A to 10A, High Performance, DC-DC Power Converters
SPECIFICATIONS: continued
Unless otherwise specified: 3.0V < VCC <5.5V, 3.0V < BST < 13.2V, ROSC = 18.7kΩ, CCOMP = 0.1µF, CSS = 0.1µF, ENABLE =
3V, CGH = CGL = 3.3nF, VFB = 1.25V, ISP = ISN = 1.25V, SWN = GND = PGND = 0V, -40°C < TAMB <85°C (Note 1)
PARAMETER
CONDITIONS
MIN TYP MAX
SOFTSTART
SS Charge Current
SS Discharge Current
COMP Discharge Current
COMP Clamp Voltage
SS Ok Threshold
SS Fault Reset
VSS = 1.5V
VSS = 1.5V
VCOMP = 0.5V, Fault Initiated
VFB < 1.0V, VSS = 2.5V
25
50
70
2
5
7
200 500
-
2.0
2.4
2.8
1.7
2.0
2.2
0.2 0.25 0.3
SS Clamp Voltage
OVER CURRENT & ZERO CURRENT COMPARATORS
Over Current Comparator
Threshold Voltage
Rail to Rail Common Mode Input
2.0
2.4
2.8
32
43
54
ISN, ISP Input Bias Current
Zero Current Comparator
Threshold
UVLO
VISP - VISN
-
60
250
2
VCC Start Threshold
VCC Stop Threshold
ENABLE
Enable Threshold
Enable Pin Source Current
GATE DRIVER
ON
OFF
2.75 2.85 2.95
2.65 2.75 2.9
1.45
0.65
0.6
4
9
GH Rise Time
VCC > 4.5V
-
40
110
GH Fall Time
VCC > 4.5V
-
40
110
GL Rise Time
VCC > 4.5V
-
40
110
GL Fall Time
VCC > 4.5V
-
40
110
GH to GL Non-Overlap Time VCC > 4.5V
0
60
140
GL to GH Non-Overlap Time VCC > 4.5V
0
60
140
VBST OK Threshold
VCC = 3.0V, FB=1.15V, Search GL High 4.0
4.8
5.0
VCC = 5.5V, FB=1.15V, Search GL High 7.3
7.8
8.3
Forced GL ON
VBST < VBST OK Threshold, FB =1.15V 200 350 650
Note 1: Specifications to -40°C are guaranteed by design, characterization and correlation with statistical process control.
UNITS
µA
µA
µA
V
V
V
V
mV
nA
mV
V
V
V
µA
ns
ns
ns
ns
ns
ns
V
V
ns
Date: 5/25/04
SP6120B Low Voltage, AnyFETTM, Synchronous, Buck Controller
3
© Copyright 2004 Sipex Corporation