English
Language : 

SI7013-A20 Datasheet, PDF (7/45 Pages) Silicon Laboratories – IC HUMIDITY AND TWO-ZONE TEMPERATURE SENSOR
Si7013-A20
Table 4. Humidity Sensor
1.9 ≤ VDD ≤ 3.6 V; TA = 30 °C; default conversion time unless otherwise noted.
Parameter
Operating Range1
Accuracy2, 3
Repeatability-Noise
Symbol
Response Time4
Drift vs. Temperature
Hysteresis
Long Term Stability3
τ63%
Test Condition
Non-condensing
0 – 80% RH
80 – 100% RH
12-bit resolution
11-bit resolution
10-bit resolution
8-bit resolution
1 m/s airflow, with cover
1 m/s airflow, without cover
Min Typ Max
0
—
100
—
±2
±3
See Figure 2.
— 0.025 —
— 0.05 —
—
0.1
—
—
0.2
—
—
18
—
—
17
—
— 0.05 —
—
±1
—
— < 0.25 —
Unit
%RH
%RH
%RH
%RH RMS
%RH RMS
%RH RMS
%RH RMS
S
%RH/°C
%RH
%RH/yr
Notes:
1. Recommended humidity operating range is 20% to 80% RH (non-condensing) over –10 °C to 60 °C. Prolonged
operation beyond these ranges may result in a shift of sensor reading with slow recovery time.
2. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See Section “4.1. Relative Humidity Sensor Accuracy” for more details.
3. Drift due to aging effects at typical room conditions of 30°C and 30% to 50% RH. May be impacted by dust, vaporized
solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging materials, etc. See Section “4.7. Long
Term Drift/Aging”
4. Response time to a step change in RH. Time for the RH output to change by 63% of the total RH change.
Rev. 1.1