English
Language : 

SI7013-A20 Datasheet, PDF (6/45 Pages) Silicon Laboratories – IC HUMIDITY AND TWO-ZONE TEMPERATURE SENSOR
Si7013-A20
Table 3. I2C Interface Specifications1 (Continued)
1.9  VDD  3.6 V; TA = –40 to +85 °C (G grade) or –40 to +125 °C (I/Y grade) unless otherwise noted.
Parameter
Symbol
Test Condition
Min
Typ Max Unit
SCL Low Time
tSKL
1.3
Start Hold Time
tSTH
0.6
Start Setup Time
tSTS
0.6
Stop Setup Time
tSPS
0.6
Bus Free Time
tBUF
Between Stop and Start
1.3
SDA Setup Time
tDS
100
SDA Hold Time
tDH
100
SDA Valid Time
tVD;DAT From SCL low to data valid
—
SDA Acknowledge Valid Time tVD;ACK From SCL low to data valid
—
Suppressed Pulse Width3
tSP
50
—
—
μs
—
—
μs
—
—
μs
—
—
μs
—
—
μs
—
—
ns
—
—
ns
—
0.9
μs
—
0.9
μs
—
—
ns
Notes:
1. All values are referenced to VIL and/or VIH.
2. Depending on the conversion command, the Si7013 may hold the master during the conversion (clock stretch). At
above 300 kHz SCL, the Si7013 may hold the master briefly for user register and device ID transactions. At the highest
I2C speed of 400 kHz the stretching will be <50 μs.
3. Pulses up to and including 50 ns will be suppressed.
Figure 1. I2C Interface Timing Diagram
6
Rev. 1.1