English
Language : 

SI7013-A20 Datasheet, PDF (4/45 Pages) Silicon Laboratories – IC HUMIDITY AND TWO-ZONE TEMPERATURE SENSOR
Si7013-A20
1. Electrical Specifications
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.
Table 1. Recommended Operating Conditions
Parameter
Symbol Test Condition
Min
Typ
Power Supply
VDD
1.9
—
Operating Temperature
TA
I and Y grade
–40
—
Operating Temperature
TA
G grade
–40
—
Max
Unit
3.6
V
+125
°C
+85
°C
Table 2. General Specifications
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or –40 to 125 °C (I/Y grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
Min
Typ
Max Unit
Input Voltage High
VIH
Input Voltage Low
VIL
AD0, SCL, SDA, VSNS pins
AD0, SCL, SDA, VSNS pins
0.7xVDD
—
—
V
—
—
0.3xVDD V
Input Voltage Range VIN SCL, SDA, VSNS pins with respect to
0.0
GND
—
VDD
V
Input Leakage
IIL
SCL, SDA pins; VIN = GND
VSNS pin (200K nominal pull up);
Vin = GND
—
—
5xVDD
1
μA
μA
Output Voltage Low VOL SDA pin; IOL = 2.5 mA; VDD = 3.3 V
—
—
0.6
V
SDA pin; IOL = 1.2 mA;
VDD = 1.9 V
—
—
0.4
V
Output Voltage High VOH VOUT pin, IOH = –0.5 mA, VDD = 2.0 V VDD – 0.2
—
—
V
VOUT pin, IOH = –10 μA
VDD– 0.1
—
—
V
VOUT pin, IOH = –1.7 mA, VDD = 3.0 V VDD – 0.4
—
—
V
Current
Consumption
IDD
RH conversion in progress
—
Temperature conversion in progress
—
150
180
μA
90
120
μA
Standby, –40 to +85 °C2
—
0.06
0.62 μA
Standby, –40 to +125 °C2
—
0.06
3.8
μA
Heater Current5
IHEAT
Peak IDD during powerup3
Peak IDD during I2C operations4
—
3.5
4.0
mA
—
3.5
4.0
mA
— 3.1 to 94.2 —
mA
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
2.
be
No
tcCoOnNvVe(rRsHio)n+ortCIO2CNVt(rTan).saction
in
progress.
Typical
values
measured
at
25
°C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Reset, Read/Write User Registers, Read EID, Read Firmware Version, Read/Write
Thermistor Coefficients and Measure Analog Voltage or Thermistor Temperature. Duration is <50 μs for all commands
except Measure Analog Voltage or Thermistor Temperature, which has <150 μs duration when Thermistor Correction is
enabled.
5. Additional current consumption when HTRE bit enabled. See Section “5.6. Heater” for more information.
4
Rev. 1.1