English
Language : 

SI5340-EVB Datasheet, PDF (6/19 Pages) Silicon Laboratories – Powered from USB port or external power supply
Si5340-EVB
8. Clock Output Circuits (OUTx/OUTxB)
Each of the 8 outputs (4 differential pairs) is AC coupled to its respective SMA connector. The output clock
termination circuit is shown in Figure 5 below. The output signal has no DC bias. If DC coupling is required, the AC
coupling capacitors can be replaced with a resistor of appropriate value. The Si5340-EVB provides pads for
optional output termination resistors and/or low frequency capacitors.
Note: Components with schematic “NI” designation are not normally populated on the Si5340-EVB and provide locations on
the PCB for optional DC/AC terminations by the end user.
Figure 5. Output Clock Termination Circuit
9. Installing ClockBuilderPro (CBPro) Desktop Software
To install the CBPro software on any Windows 7 (or later version) PC, do the following:
1. Go to http://www.silabs.com/CBPro/ and download ClockBuilderPro™ software.
2. Installation instructions and User’s Guide for ClockBuilderPro™ can be found at the download link shown
above. Please follow the instructions as indicated.
10. Using the Si5340 EVB
10.1. Connecting the EVB to Your Host PC
Once the ClockBuilderPro™ software in installed, connect the PC to the EVB with a USB cable as illustrated in
Figure 6.
Figure 6. EVB Connection Diagram
6
Rev. 1.0