ï® Absolute Maximum Ratings
Table 7
Item
Symbol
Ratings
Unit
Power supply voltage
VCC
â0.3 to +7.0
V
Input voltage
VIN
â0.3 to VCC + 0.3
V
Output voltage
VOUT
â0.3 to VCC
V
Operating ambient temperature
Topr
â40 to +125
°C
Storage temperature
Tstg
â65 to +150
°C
Caution The absolute maximum ratings are rated values exceeding which the product could suffer physical
damage. These values must therefore not be exceeded under any conditions.
ï® Recommended Operating Conditions
Table 8
Item
Power supply voltage
High level input voltage
Low level input voltage
Symbol
VCC
VIH
VIL
Condition
READ, EWDS
WRITE, ERASE ,
WRAL, ERAL, EWEN
â¯
â¯
Ta = â40°C to +125°C
Unit
Min.
Max.
2.7
5.5
V
2.7
5.5
V
0.8 Ã VCC
VCC
V
0.0
0.2 Ã VCC
V
ï® Pin Capacitance
Item
Input Capacitance
Output Capacitance
Table 9
Symbol
CIN
COUT
Condition
VIN = 0 V
VOUT = 0 V
(Ta = +25°C, f = 1.0 MHz, VCC = 5.0 V)
Min.
Max.
Unit
â¯
8
pF
â¯
10
pF
ï® Endurance
Table 10
Item
Symbol
Operating Ambient Temperature
Ta = â40°C to +85°C
Endurance
NW
Ta = â40°C to +105°C
Ta = â40°C to +125°C
*1. For each address (Word: 16 bits)
Min.
106
8 Ã 105
5 Ã 105
Max.
â¯
â¯
â¯
Unit
cycles / word*1
cycles / word*1
cycles / word*1
ï® Data Retention
Table 11
Item
Symbol
Operating Ambient Temperature
Min.
Max.
Unit
Data Retention
â¯
Ta = +25°C
Ta = â40°C to +125°C
100
â¯
year
50
â¯
year
6
Seiko Instruments Inc.
|
▷ |