S93A46A Datasheet, PDF (6/41 Pages) Seiko Instruments Inc – 125C OPERATION 3-WIRE SERIAL
125°C OPERATION 3-WIRE SERIAL E2PROM FOR AUTOMOTIVE
S-93A46A/56A/66A
Rev.6.1_00
 Absolute Maximum Ratings
Table 7
Item
Symbol
Ratings
Unit
Power supply voltage
VCC
−0.3 to +7.0
V
Input voltage
VIN
−0.3 to VCC + 0.3
V
Output voltage
VOUT
−0.3 to VCC
V
Operating ambient temperature
Topr
−40 to +125
°C
Storage temperature
Tstg
−65 to +150
°C
Caution The absolute maximum ratings are rated values exceeding which the product could suffer physical
damage. These values must therefore not be exceeded under any conditions.
 Recommended Operating Conditions
Table 8
Item
Power supply voltage
High level input voltage
Low level input voltage
Symbol
VCC
VIH
VIL
Condition
READ, EWDS
WRITE, ERASE ,
WRAL, ERAL, EWEN
⎯
⎯
Ta = −40°C to +125°C
Unit
Min.
Max.
2.7
5.5
V
2.7
5.5
V
0.8 × VCC
VCC
V
0.0
0.2 × VCC
V
 Pin Capacitance
Item
Input Capacitance
Output Capacitance
Table 9
Symbol
CIN
COUT
Condition
VIN = 0 V
VOUT = 0 V
(Ta = +25°C, f = 1.0 MHz, VCC = 5.0 V)
Min.
Max.
Unit
⎯
8
pF
⎯
10
pF
 Endurance
Table 10
Item
Symbol
Operating Ambient Temperature
Ta = −40°C to +85°C
Endurance
NW
Ta = −40°C to +105°C
Ta = −40°C to +125°C
*1. For each address (Word: 16 bits)
Min.
106
8 × 105
5 × 105
Max.
⎯
⎯
⎯
Unit
cycles / word*1
cycles / word*1
cycles / word*1
 Data Retention
Table 11
Item
Symbol
Operating Ambient Temperature
Min.
Max.
Unit
Data Retention
⎯
Ta = +25°C
Ta = −40°C to +125°C
100
⎯
year
50
⎯
year
6
Seiko Instruments Inc.