English
Language : 

S93A46A Datasheet, PDF (14/41 Pages) Seiko Instruments Inc – 125C OPERATION 3-WIRE SERIAL
125°C OPERATION 3-WIRE SERIAL E2PROM FOR AUTOMOTIVE
S-93A46A/56A/66A
Rev.6.1_00
4. 3 Erasing data (ERASE)
To erase 16-bit data at a specified address, set all 16 bits of the data to 1, change CS to high, and then input the
ERASE instruction and address following the start bit. There is no need to input data. The data erase operation
starts when CS goes low. When the clocks more than the specified number have been input, the clock pulse
monitoring circuit cancels the ERASE instruction. For details of the clock pulse monitoring circuit, refer to “
Function to Protect Against Write due to Erroneous Instruction Recognition”.
tCDS
CS
Verify
Standby
SK
1 2 34 5 67 8 9
DI
<1> 1 1 A5 A4 A3 A2 A1
A0
High-Z
DO
tSV
busy
ready
tHZ1
tPR
High-Z
Figure 10 Data Erase Timing (S-93A46A)
CS
tCDS
Verify
Standby
SK
1 2 3 4 5 6 7 8 9 10 11
DI
<1> 1 1
A6 A5 A4 A3 A2 A1 A0
DO
High-Z
x:S-93A56A
A7:S-93A66A
tSV
busy
ready
tHZ1
tPR
High-Z
Figure 11 Data Erase Timing (S-93A56A, S-93A66A)
14
Seiko Instruments Inc.