S-24C02DI-J8T1U5 Datasheet, PDF (6/47 Pages) Seiko Instruments Inc – Write protect function during low power supply voltage | |||
|
◁ |
2-WIRE SERIAL E2PROM
S-24C02D/04D/08D16D
Rev.3.0_01_U
ï® Absolute Maximum Ratings
Table 1
Item
Symbol
Absolute Maximum Rating
Unit
Power supply voltage
VCC
â0.3 to +6.5
V
Input voltage
VIN
â0.3 to +6.5
V
Output voltage
VOUT
â0.3 to +6.5
V
Operation ambient temperature
Topr
â40 to +85
°C
Storage temperature
Tstg
â65 to +150
°C
Caution The absolute maximum ratings are rated values exceeding which the product could suffer physical
damage. These values must therefore not be exceeded under any conditions.
ï® Recommended Operating Conditions
Table 2
Item
Power supply voltage
High level input voltage
Low level input voltage
Symbol
Condition
VCC
Read
Write
VIH
VCC = 1.7 V to 5.5 V
VIL
VCC = 1.7 V to 5.5 V
Ta = â40°C to +85°C
Min.
Max.
Unit
1.7
5.5
V
1.7
5.5
V
0.7 Ã VCC
5.5
V
â0.3
0.3 Ã VCC
V
ï® Pin Capacitance
Item
Input capacitance
I/O capacitance
Symbol
CIN
CI/O
Table 3
(Ta = +25°C, f = 1.0 MHz, VCC = 5.0 V)
Condition
Min.
Max.
Unit
VIN = 0 V (S-24C02D: SCL, A0, A1, A2, WP)
â
8
pF
VIN = 0 V (S-24C04D: SCL, A1, A2, WP)
â
8
pF
VIN = 0 V (S-24C08D: SCL, A2, WP)
â
8
pF
VIN = 0 V (S-24C16D: SCL, WP)
â
8
pF
VI/O = 0 V (SDA)
â
8
pF
ï® Endurance
Table 4
Item
Symbol Operation Ambient Temperature
Min.
Endurance
NW
Ta = +25°C
106
*1. For each address (Word: 8-bit)
Max.
â
Unit
cycle / word*1
ï® Data Retention
Table 5
Item
Symbol Operation Ambient Temperature
Min.
Max.
Unit
Data retention
â
Ta = +25°C
100
â
year
6
|
▷ |