English
Language : 

S-8204AAB-TCT1Y Datasheet, PDF (24/34 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC
BATTERY PROTECTION IC FOR 3-SERIES OR 4-SERIES CELL PACK
S-8204A Series
Rev.3.5_00
3. 7-Series Cell
EB+
R2
R3
Charge FET
Discharge FET
RCOP
DCOP
RDOP
M6
1 COP
2 VMP
RINV3
RVINI1
CCDT1
CCCT1
RCIT1
3 DOP
4 VINI
5 CDT
6 CCT
7 CIT
8 SEL
CTLC 16
CTLD 15
VDD 14
VC1 13
VC2 12
VC3 11
VC4 10
VSS 9
RSEL1 S-8204A (1)
CVC1
CVC2
CVC3
CVC4
RVC1
RVC2
RVC3
RVC4
CVSS1
RVSS1
CEB+
REB+
M3
M1
M5
RINV2 RINV1
ZD1
EB−
M4
M2
R1
RIFD
RIFC
RVINI2
CCDT2
CCCT2
CCIT2
1 COP
2 VMP
3 DOP
4 VINI
5 CDT
6 CCT
7 CIT
8 SEL
CTLC 16
CTLD 15
VDD 14
VC1 13
VC2 12
VC3 11
VC4 10
VSS 9
CVC5
CVC6
CVC7
RSEL2 S-8204A (2)
RSENSE
Figure 14
RCTLD RCTLC
RVC5
RVC6
RVC7
RVC8
CVSS2
RVSS2
Caution 1. It is recommended that filter constants between VDD pin and VSS pin should be set
approximately to 47 μF • Ω.
e.g., CVSS × RVSS = 1.0 μF × 47 Ω = 47 μF • Ω
Sufficient evaluation of transient power supply fluctuation and overcurrent protection
function with the actual application is needed to determine the proper constants. Contact our
sales office in case the constants should be set to other than 47 μF • Ω.
2. It has not been confirmed whether the operation is normal in circuits other than the above
example of connection. In addition, the example of connection shown above and the
constants do not guarantee proper operation. Perform thorough evaluation using an actual
application to set the constants.
Remark Refer to the application note for constants of each external component.
24