S-8215A Series
 Operation
Remark Refer to " Battery Protection IC Connection Examples".
1. Normal status
If the voltage of each of the batteries is lower than "the overcharge detection voltage n (VCUn) + the overcharge
hysteresis voltage n (VHCn)", the CO pin output changes to "L" (Active "H") or "H" (Active L"). This is called normal
status.
2. Overcharge status
When the voltage of one of the batteries exceeds VCUn during charging under normal conditions and the status is
retained for the overcharge detection delay time (tCU) or longer, the CO pin output changes. This is called overcharge
status. Connecting FET to the CO pin provides charge control and a second protection.
If the voltage of each of the batteries is lower than VCUn + VHCn and the status is retained for 2.0 ms typ. or longer, the
S-8215A Series changes to normal status.
3. Overcharge timer reset function
When an overcharge release noise that forces the voltage of one of the batteries temporarily below VCUn is input during
tCU from when VCUn is exceeded to when charging is stopped, tCU is continuously counted if the time the overcharge
release noise persists is shorter than the overcharge timer reset delay time (tTR). Under the same conditions, if the time
the overcharge release noise persists is tTR or longer, counting of tCU is reset once. After that, when VCUn has been
exceeded, counting tCU resumes.
11