S-8215AAA-K8T2U Datasheet, PDF (1/29 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 3-SERIAL TO 5-SERIAL CELL PACK | |||
|
S-8215A Series
www.sii-ic.com
BATTERY PROTECTION IC FOR 3-SERIAL TO 5-SERIAL CELL PACK
(SECONDARY PROTECTION)
© SII Semiconductor Corporation, 2010-2016
Rev.2.3_02
The S-8215A Series is used for secondary protection of lithium-ion rechargeable batteries, and incorporates high-accuracy
voltage detection circuits and delay circuits.
Short-circuiting between cells makes it possible for serial connection of three cells to five cells.
ï® Features
⢠High-accuracy voltage detection circuit for each cell
Overcharge detection voltage n (n = 1 to 5)
3.60 V to 4.70 V (50 mV step)
Accuracy ±25 mV (Ta = +25°C)
Accuracy ±30 mV (Ta = â5°C to +55°C)
Overcharge hysteresis voltage n (n = 1 to 5)
0.0 mV to â550 mV (50 mV step)
â300 mV to â550 mV
Accuracy ±20%
â100 mV to â250 mV
Accuracy ±50 mV
0.0 mV to â50 mV
Accuracy ±25 mV
⢠Delay times for overcharge detection can be set by an internal circuit only (External capacitors are unnecessary).
⢠Output form is selectable:
CMOS output, Nch open-drain output, Pch open-drain output
⢠Output logic is selectable:
Active "H", active "L"
⢠High-withstand voltage:
Absolute maximum rating 28 V
⢠Wide operation voltage range:
3.6 V to 26 V
⢠Wide operation temperature range: Ta = â40°C to +85°C
⢠Low current consumption
At VCUn â 1.0 V for each cell:
At 2.3 V for each cell:
3.0 μA max. (Ta = +25°C)
1.7 μA max. (Ta = +25°C)
⢠Lead-free (Sn 100%), halogen-free
ï® Application
⢠Lithium-ion rechargeable battery pack (for secondary protection)
ï® Packages
⢠TMSOP-8
⢠SNT-8A
1
|
▷ |