SLX24C01 Datasheet, PDF (9/27 Pages) Siemens Semiconductor Group – 1/2 Kbit 128/256 x 8 bit Serial CMOS EEPROMs, I2C Synchronous 2-Wire Bus
SLx 24C01/02/P
4
Device Addressing and EEPROM Addressing
After a START condition, the master always transmits a Command Byte CSW or CSR.
After the acknowledge of the EEPROM a Control Byte follows, its content and the
transmitter depend on the previous Command Byte. The description of the Command
and Control Bytes is shown in table 2.
Command Byte
Control Byte
Selects operation: the least significant bit b0 is low for a write
operation (Chip Select Write Command Byte CSW) or set high for a
read operation (Chip Select Read Command Byte CSR). In both
Command Bytes, the bit positions b3 to b1 are left undefined.
Following CSW (b0 = 0): contains the seven or eight lower bits of
the EEPROM address (EEA) bit A6 or A7 to A0, or an additional
command byte for the handling of the protection bit.
Following CSR (b0 = 1): contains the data read out, transmitted by
the EEPROM. The EEPROM data are read as long as the master
pulls down SDA after each byte in order to acknowledge the
transfer. The read operation is stopped by the master by releasing
SDA (no acknowledge is applied) followed by a STOP condition.
Table 2
Command and Control Byte for I2C-Bus Addressing of Chip and EEPROM
CSW
CSR
EEA
Definition
Function
b7 b6 b5 b4 b3 b2 b1 b0
1 0 1 0 x x x 0 Chip Select for Write
1 0 1 0 x x x 1 Chip Select for Read
A7 A6 A5 A4 A3 A2 A1 A0 EEPROM address
The device has an internal address counter which points to the current EEPROM
address.
The address counter is incremented
– after a data byte to be written has been acknowledged, during entry of further data
byte
– during a byte read, thus the address counter points to the following address after
reading a data byte.
Semiconductor Group
9
1998-07-27