English
Language : 

SDA9362 Datasheet, PDF (15/39 Pages) Siemens Semiconductor Group – DDC-PLUS-Deflection Controller
SDA 9362
2.5.3 I2C-Bus Commands
Control Item
D7 D6 D5 D4 D3 D2 D1 D0 Allowed Effective Can be Default Unit
Range Range Disabled Value if
by Bit Disabled
Deflection control 0
00H
see below
–
–
–
–
–
Deflection control 1
01H
see below
–
–
–
–
–
Vertical shift
02H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
Vertical size
03H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
Vertical linearity
04H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
Vertical S-correction
05H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
Vertical EHT
compensation 1)
06H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
Horizontal size
07H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
Pin phase
08H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
Pin amp
09H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
Upper corner pin
0AH B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
correction
Lower corner pin
0BH B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
correction
Horizontal EHT
0CH B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
–
compensation 1)
Horizontal shift
0DH B6 B5 B4 B3 B2 B1 B0 X -64..63 -64..63
–
–
Vertical angle
0EH B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
Vertical bow
0FH B7 B6 B5 B4 B3 B2 B1 B0 -128..127 -128..127 –
–
Vertical blanking time 1) 10H X B6 B5 B4 B3 B2 B1 B0 0..127
a) BSE = 0 b)
Horizontal blanking time 11H X X B5 B4 B3 B2 B1 B0 0..63 0..63 BSE = 0 H-flyback
Horizontal blanking
12H B5 B4 B3 B2 B1 B0 X X -32..31 -32..31
–
–
phase
1/CLL
–
–
lines
4/CLL
4/CLL
Start vertical scan 1)
13H B7 B6 B5 B4 B3 B2 B1 B0 -128..127 c)
SSE = 0
9
line
Vertical scan width 0 1) 14H X X X X X X B9 B8 0..3
d) STE = 0 e) 256 lines
Vertical scan width 1 1) 15H B7 B6 B5 B4 B3 B2 B1 B0 0..255
d) STE = 0 e)
lines
Guard band 1)
16H X X B5 B4 B3 B2 B1 B0 0..63 0..63 GBE = 0 3 half lines
Start reduced scan 1) 17H X X B5 B4 B3 B2 B1 B0 0..63 0, 2..63 SRSE =
2
line
0
Vertical sync control
18H
see below
–
–
–
Min..No. of lines / field 1) 19H B7 B6 B5 B4 B3 B2 B1 B0 0..255 0..255
–
Max. No. of lines / field 1) 1AH B7 B6 B5 B4 B3 B2 B1 B0 0..255 0..255
–
AFC EHT
compensation 1)
1BH B5 B4 B3 B2 B1 B0 X X -32..31 -32..31
–
–
–
–
2 lines
–
2 lines
–
–
Internal voltage Ref
48H
control
see below
–
–
–
–
–
1) see 2.5.5: Explanation of some control items
Semiconductor Group
15
1998-02-01