SKYPER32PROR_0701 Datasheet, PDF (9/18 Pages) Semikron International – IGBT Driver Core
SKYPER™ 32PRO R
Under Voltage Reset (UVR)
The Under Voltage Reset circuit configures the driver core to hold in a reset state during power on and power off. UVR can
be thought of as a supplement function to the build in power-on-reset by the user. While in reset, the driver is held in its initial
condition until PRIM_nPWRFAIL_IN is forced into HIGH state. Once the system reset sequence completes, the driver core
is ready to operate.
UVR input
Application Hints
A capacitor is connected to the input to obtain high noise
immunity.
Disabling of the Under Voltage Reset function
(PRIM_nPWRFAIL_IN) can be achieved by no connection or
connection to +15V.
Please note:
Do not use PRIM_nPWRFAIL_IN to place the driver core into halt mode during operation.
Under Voltage Protection (UVP) primary
The internally detected supply voltage of the driver has an under voltage protection. The table below gives an overview of
the trip level.
Supply voltage
Regulated +15V ±4%
UVP level
13,5V
If the internally detected supply voltage of the driver falls below this level, the IGBTs will be switched off (IGBT driving
signals set to LOW). The input side switching signals of the driver will be ignored. The error memory will be set, and the
output PRIM_HOLD_OUT changes to the HIGH state.
Under Voltage Protection secondary
This function monitors the rectified voltage on the secondary side. If the voltage drops, the IGBTs will be switched off (IGBT
driving signal set to LOW). The input side switching signals of the driver will be ignored. No failure message will be
generated.
Output voltage
Regulated +15V
UVP level
12V
Input Signals
The signal transfer to each IGBT is made with pulse transformers, used for switching on and switching off of the IGBT. The
inputs have a Schmitt Trigger characteristic and a positive / active high logic (input HIGH = IGBT on; input LOW = IGBT off).
It is mandatory to use circuits which switch active to +15V and 0V. Pull up and open collector output stages must not be
used for TOP / BOT control signals. It is recommended choosing the line drivers according to the demanded length of the
signal wires.
Please note:
It is not permitted to apply switching pulses shorter than 1µs.