English
Language : 

SKM200GB124 Datasheet, PDF (2/6 Pages) Semikron International – Low Loss IGBT Modules
SKM 200 GB 124 D
1400
W
1200
M200G124.X LS-1
1000
800
600
400
200
Ptot
0
0 20 40 60 80 100 120 140 160
TC
°C
Fig. 1 Rated power dissipation Ptot = f (TC)
70
mWs
60
50
T = 125 °C M200G124.XLS-2
j
Eon VCE = 600 V
VGE = + 15 V
RG = 7 Ω
40
Eof f
30
20
10
E
0
0 50
IC
100 150 200 250
Fig. 2 Turn-on /-off energy = f (IC)
300 350
A
90
mW s
80
70
60
M200G124.X LS-3
Eon
Tj = 125 °C
VCE = 600 V
VGE = + 15 V
IC = 150 A
1000
A
100
M200G124.X LS -4
tp=10µs
1 pulse
TC = 25 °C
Tj ≤ 150 °C
100µs
50
40
30
Eof f
20
10
E
0
0 RG 10
20
30
40
50 Ω 60
10
IC
1
1
VCE 10
1ms
Not for
linear use
10ms
100
1000 V 10000
Fig. 3 Turn-on /-off energy = f (RG)
Fig. 4 Maximum safe operating area (SOA) IC = f (VCE)
M200G124.X LS -5
M200G124.X LS -6
2,5
Tj ≤ 150 °C
12
Tj ≤ 150 °C
VGE = 15 V
VGE = ± 15 V
2
RGoff = 7 Ω
10
IC = 150 A
tsc ≤ 10 µs
L < 25 nH
di/dt= 1000 A/µs
8
3000 A/µs
IC = 150 A
1,5
5000 A/µs
6
1
allowed numbers of
4
short circuits: <1000
0,5
ICpuls/IC
0
0 200 400 600 800 1000 1200 1400
VCE
V
Fig. 5 Turn-off safe operating area (RBSOA)
2
ICSC/IC
time between short
circuits: >1s
0
0 200 400 600 800
VCE
1000 1200 1400
V
Fig. 6 Safe operating area at short circuit IC = f (VCE)
B 6 – 158
0898
© by SEMIKRON