DS17H732S Datasheet, PDF (8/20 Pages) Sanyo Semicon Device – 3-PHASE STEPPING SYSTEMS
3-phase STEPPING SYSTEMS
DC input
System configuration
Operation, connection, and function
Each section name of the driver
1 DC source connectorʢCN2ʣ
ɹ ʜʜʜConnect the DC source.
2 Stepping motor output connectorʢCN3ʣ
ɹ ʜʜʜConnect the stepping motor drive line.
3 I/O signal connectorʢCN1Aʣ
ɹ ʜʜʜConnect the I/O signal.
4 Function selection DIP switchpackʢSL, F/R, A, B, Cʣ
ɹ ʜʜʜSelect the function depending on your specification.
3 I/O signal function
Signal nameʢabbreviationʣ
Pulse inputʢCWʣ
Pulse inputʢCCWʣ
Power down inputʢPDʣ
Rotation monitor outputʢMONʣ
Pin numberʢCN1Aʣ
PMDSA1S3P01
1
2
3
4
5
6
MONʢcollectorʣ7
MONʢcollectorʣ8
Function
Inputs the drive pulse for the rotation in the CW direction.
Inputs the drive pulse for the rotation in the CCW direction.
Inputting the PD signal turns off the current that flows through the stepping motor.
Photo coupler input method : Internal photo coupler ONʜʜ PD function enabled
Indicates ON when the exciting phase is at the origin position.
In the full-step, outputs once for every 6 pulses.
˔ The CW direction of the rotation of the stepping motor is the clockwise direction when viewing the stepping motor from the output axis sideʢflange sideʣ.
The CCW direction is the counterclockwise direction when viewing the stepping motor from the output axis sideʢflange sideʣ.
4 Function selection DIP switchpack
1
2
3
4
5
ŋ The factory settings are shown in the
figure above.
ŋ Before changing the settings of the
function selection DIP switches, turn off
the source of the PM driver.
1 SLʢauto current down selectionʣ
Select the auto current down function.
SL
Automatic current reduction
ON
100 % of current rating when stopped
OFF Approx. 50 % of current rating when stopped
Note 1Ê£The temperature increase in the
motor driver can be controlled
by setting SL to OFFÊ¢approx. 50 %
of the rated currentʣ.
Note 2Ê£The output torque when SL is OFF
ʢapprox. 50 % of the rated currentʣ
is approx. 50 % of that when SL is
ONʢ100 % of the rated currentʣ.
2 F/R selectionʢNoteʣ
This switch is not used.
Do not set it to OFF.
3ɾ4ɾ5 A, B, Cʢstep angle settingʣ
Set the step angle
A
ON
ON
OFF
OFF
OFF
DIP switch
B
C
ON
OFF
OFF
ON
OFF
OFF ON
Step angle
Basic step angle 1/1ʢ1.2˃pulseʣ
Basic step angle 1/2ʢ0.6˃pulseʣ
Basic step angle 1/4ʢ0.3˃pulseʣ
Basic step angle 1/8ʢ0.15˃pulseʣ
Basic step angle 1/16ʢ0.075˃pulseʣ
Number of drive pulses per one period
of phase current
6
12
24
48
48
ŋ When the DIP switch lCz = lONzʢ1/16 divisionʣ, the internal circuitʢstepping motorʣ
operates at the rising edge and falling edge of the drive pulse. If the duty ratio of the
drive pulse moves out of the adjustment significantly by 50 %, operation becomes
unstable.
7