|
DS17H732S Datasheet, PDF (8/20 Pages) Sanyo Semicon Device – 3-PHASE STEPPING SYSTEMS | |||
|
◁ |
3-phase STEPPING SYSTEMS
DC input
System conï¬guration
Operation, connection, and function
Each section name of the driver
1 DC source connectorʢCN2ʣ
ɹ ÊÊÊConnect the DC source.
2 Stepping motor output connectorʢCN3ʣ
ɹ ÊÊÊConnect the stepping motor drive line.
3 I/O signal connectorʢCN1Aʣ
ɹ ÊÊÊConnect the I/O signal.
4 Function selection DIP switchpackʢSL, F/R, A, B, Cʣ
ɹ ÊÊÊSelect the function depending on your speciï¬cation.
3 I/O signal function
Signal nameʢabbreviationʣ
Pulse inputʢCWʣ
Pulse inputʢCCWʣ
Power down inputʢPDʣ
Rotation monitor outputʢMONʣ
Pin numberʢCN1Aʣ
PMDSA1S3P01
1
2
3
4
5
6
MONʢcollectorʣ7
MONʢcollectorʣ8
Function
Inputs the drive pulse for the rotation in the CW direction.
Inputs the drive pulse for the rotation in the CCW direction.
Inputting the PD signal turns off the current that ï¬ows through the stepping motor.
Photo coupler input method : Internal photo coupler ONÊÊ PD function enabled
Indicates ON when the exciting phase is at the origin position.
In the full-step, outputs once for every 6 pulses.
Ë The CW direction of the rotation of the stepping motor is the clockwise direction when viewing the stepping motor from the output axis sideÊ¢ï¬ange sideÊ£.
The CCW direction is the counterclockwise direction when viewing the stepping motor from the output axis sideÊ¢ï¬ange sideÊ£.
4 Function selection DIP switchpack
1
2
3
4
5
Å The factory settings are shown in the
ï¬gure above.
Å Before changing the settings of the
function selection DIP switches, turn off
the source of the PM driver.
1 SLʢauto current down selectionʣ
Select the auto current down function.
SL
Automatic current reduction
ON
100 % of current rating when stopped
OFF Approx. 50 % of current rating when stopped
Note 1Ê£The temperature increase in the
motor driver can be controlled
by setting SL to OFFÊ¢approx. 50 %
of the rated currentʣ.
Note 2Ê£The output torque when SL is OFF
ʢapprox. 50 % of the rated currentʣ
is approx. 50 % of that when SL is
ONʢ100 % of the rated currentʣ.
2 F/R selectionʢNoteʣ
This switch is not used.
Do not set it to OFF.
3ɾ4ɾ5 A, B, Cʢstep angle settingʣ
Set the step angle
A
ON
ON
OFF
OFF
OFF
DIP switch
B
C
ON
OFF
OFF
ON
OFF
OFF ON
Step angle
Basic step angle 1/1Ê¢1.2ËpulseÊ£
Basic step angle 1/2Ê¢0.6ËpulseÊ£
Basic step angle 1/4Ê¢0.3ËpulseÊ£
Basic step angle 1/8Ê¢0.15ËpulseÊ£
Basic step angle 1/16Ê¢0.075ËpulseÊ£
Number of drive pulses per one period
of phase current
6
12
24
48
48
ŠWhen the DIP switch lCz = lONzʢ1/16 divisionʣ, the internal circuitʢstepping motorʣ
operates at the rising edge and falling edge of the drive pulse. If the duty ratio of the
drive pulse moves out of the adjustment signiï¬cantly by 50 %, operation becomes
unstable.
7
|
▷ |