English
Language : 

BU97530KVT Datasheet, PDF (35/59 Pages) Rohm – Built-in OSC circuit
BU97530KVT
Datasheet
In this technique, the controller uses interrupts to determine key on/off states and read the key data. The controller must check
the SDO state when SCE is low. If SDO is low, the controller recognizes that a key has been pressed and executes the key data
read operation. After that the next key on/off determination is performed after the time t8 has elapsed by checking the SDO state
when SCE is low and reading the key data. The period t8 in this technique must satisfy t8 > t4.
If a key data read operation is executed when SDO is high, the read key data (KD1 to KD30) and sleep acknowledge data
(SA) will be invalid.
Key Input 1
Key scan
SCE
Key on
t3
t6
Key on
t3
t4
t3
t6
t6
t6
SDI
t5
t5
t5
t5
SDDO0
Key data read
Key data read request
t8
Controller determination
Controller determination
(key on)
(key on)
t8
Controller determination
(key on)
t8
Controller determination
(key on)
t8
Controller determination
(key on)
t3: Key scan execution time when the key data agreed for two key scans. (9840T(s))
t4: Key scan execution time when the key data did not agree for two key scans and the key scan was executed again.
(19680T(s)) T = 1 / fosc
t5: Key address (43H) transfer time
t6: Key data read time
Figure 23. Interrupt Based Key Data Read Operation
www.rohm.com
© 2014 ROHM Co., Ltd. All rights reserved.
TSZ22111・15・001
35/56
TSZ02201-0P4P0D300570-1-2
02.Mar.2015 Rev.003