English
Language : 

RF5410 Datasheet, PDF (23/33 Pages) RF Micro Devices – LTE MMMB PA Module
RFMD + TriQuint = Qorvo
Register
Address
Register
Name
Reg 26
RFFE_STATUS
Reg 27
Reg 27
GROUP_SID
GROUP_SID
Reg 28
PM_TRIG
Reg 28
PM_TRIG
Reg 28
PM_TRIG
Reg 28
Reg 28
PM_TRIG
PM_TRIG
Data
Bit
0
7:4
3:0
7:6
5
4
3
2
Field Name
BID_GID_ERR
RESERVED
GSID
PWR_MODE
Trigger_Mask_2
Trigger_Mask_1
Trigger_Mask_0
Trigger_2
Description
Default
Read Command Sequence received with a
BROADCAST_ID or GROUP_SID.
Reserved
Group slave ID
00: ACTIVE – Normal Operation
01: STARTUP – Reset all registers to default
settings
10: LOW POWER – Retain register values,
Band-Gap off
11: Reserved
Note: Setting PWR_MODE to STARTUP is
identical to a hardware reset initiated by the VIO
signal.
If set, Trigger_2 is masked (disabled). When
Trigger_Mask_2, Trigger_Mask_1, and
Trigger_Mask_0, are all set, data goes directly to
the destination (no trigger required).
If set, Trigger_1 is masked (disabled). When
Trigger_Mask_2, Trigger_Mask_1, and
Trigger_Mask_0, are all set, data goes directly to
the destination (no trigger required).
If set, Trigger_0 is masked (disabled). When
Trigger_Mask_2, Trigger_Mask_1, and
Trigger_Mask_0, are all set, data goes directly to
the destination (no trigger required).
Write 1 to this bit to load T2 triggered registers.
0b0
0b0000
0b0000
0b00
0b0
0b0
0b0
0b0
Reg 28
PM_TRIG
1
Trigger_1
Write 1 to this bit to load T1 triggered registers.
0b0
Reg 28
PM_TRIG
0
Trigger_0
Write 1 to this bit to load T0 triggered registers.
0b0
Reg 29
PRODUCT_ID 7:0
PRODUCT_ID
Read only. During programming of USID, a
write command sequence is performed on this
register but does not change its value.
Reg 30
MANUFACTUR
ER_ID
7:0
MANUFACTURE
R_ID[7:0]
Read only. During programming of USID, a
write command sequence is performed on this
register but does not change its value.
Reg 31
MAN_USID
7:6
RESERVED
Reserved
Reg 31
MAN_USID
5:4
MANUFACTURE
R_ID[9:8]
Read only. During programming of USID, a
write command sequence is performed on this
register but does not change its value.
Reg 31
MAN_USID
3:0
USID
USID of the device = “PA Module 1”.
Can be changed using the USID write sequence.
Note:
Column Special Support: Bdcst_ID = addressable by USID 0000 (Broadcast ID), GSID = addressable by GSID,
T0 = Trigger_0, T1 = Trigger_1, T2 = Trigger_2
0b1101_
1111
(0xDF)
0b0011_
0100
(0x34)
0b00
0b01
0b1111
Special
Support
No
No
No
Bdcst_ID
No
No
No
Bdcst_ID,
GSID
Bdcst_ID,
GSID
Bdcst_ID,
GSID
No
No
No
No
No
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R/W
RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421
DS20160809
For sales or technical support, contact RFMD at +1.336.678.5570 or customerservice@rfmd.com.
The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of
third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended
application circuitry and specifications at any time without prior notice.
23 of 33