5. Electrical Characteristics
Table 5.11 High-speed On-Chip Oscillator Circuit Electrical Characteristics
Symbol
Parameter
Condition
â
High-speed on-chip oscillator frequency after VCC = 2.7 V to 5.5 V,
reset
â40°C ⤠Topr ⤠85°C (J version) /
High-speed on-chip oscillator frequency when â40°C ⤠Topr ⤠125°C (K version)
the FRA4 register correction value is written
into the FRA1 register and the FRA5 register
correction value into the FRA3 register (3)
High-speed on-chip oscillator frequency when
the FRA6 register correction value is written
into the FRA1 register and the FRA7 register
correction value into the FRA3 register
High-speed on-chip oscillator frequency
temperature ⢠supply voltage dependence (2)
â
Oscillation stabilization time
â
Self power consumption at oscillation
VCC = 5.0 V, Topr = 25°C
Standard
Min.
Typ.
Max.
â
40
â
â
36.864
â
â
32
â
â5
â
5
â
200
â
â
400
â
Unit
MHz
MHz
MHz
%
µs
µA
Notes:
1. The measurement condition is VCC = 2.7 to 5.5 V and Topr = â40 to 85°C (J version) / â40 to 125°C (K version).
2. This indicates the precision error for the oscillation frequency of the high-speed on-chip oscillator.
3. This enables the setting errors of bit rates such as 9600 bps and 38400 bps to be 0% when the serial interface is used in
UART mode.
Table 5.12 Low-speed On-Chip Oscillator Circuit Electrical Characteristics
Symbol
Parameter
Condition
Standard
Unit
Min. Typ. Max.
fOCO-S
Low-speed on-chip oscillator frequency
112.5 125 137.5 kHz
fOCO-WDT Low-speed on-chip oscillator frequency for watchdog
timer
112.5 125 137.5 kHz
â
Oscillation stabilization time
VCC = 5.0 V, Topr = 25°C
â
30
100 µs
â
Self power consumption at oscillation
VCC = 5.0 V, Topr = 25°C
â
3
â
µA
Note:
1. The measurement condition is VCC = 2.7 to 5.5 V and Topr = â40 to 85°C (J version) / â40 to 125°C (K version).
Table 5.13 Power Supply Circuit Timing Characteristics
Symbol
td(P-R)
Parameter
Time for internal power supply stabilization during
power-on (2)
Condition
Standard
Unit
Min. Typ. Max.
â
â 2000 µs
Notes:
1. The measurement condition is VCC = 2.7 to 5.5 V and Topr = â40 to 85°C (J version) / â40 to 125°C (K version).
2. Wait time until the internal power supply generation circuit stabilizes during power-on.
R01DS0012EJ0110 Rev.1.10
Jan 31, 2013
Page 52 of 67
|
▷ |