English
Language : 

HD74LV4040A Datasheet, PDF (5/11 Pages) Hitachi Semiconductor – 12-stage Binary Counter
HD74LV4040A
Timing Diagram
CLR
Q1
Q2
Q3
Q4
Q5
Q6
Q7
Q8
Q9
Q10
Q11
Q12
CLEAR
1
2
3
4
8
16
32
64 128 256 512 1024 2048 4096
COUNT
CLEAR
DC Electrical Characteristics
Ta = –40 to 85°C
Item
Symbol VCC (V)*
Min
Typ
Max
Unit Test Conditions
Input voltage
Output voltage
Input current
Quiescent supply
current
VIH
2.0
1.5
—
2.3 to 2.7 VCC×0.7 —
3.0 to 3.6 VCC×0.7 —
4.5 to 5.5 VCC×0.7 —
VIL
2.0
—
—
2.3 to 2.7 —
—
3.0 to 3.6 —
—
4.5 to 5.5 —
—
VOH
Min to Max VCC–0.1 —
2.3
2.0
—
3.0
2.48
—
4.5
3.8
—
VOL
Min to Max —
—
2.3
—
—
3.0
—
—
4.5
—
—
IIN
0 to 5.5
—
—
ICC
5.5
—
—
—
V
—
—
—
0.5
VCC×0.3
VCC×0.3
VCC×0.3
—
V
—
—
—
0.1
0.4
0.44
0.55
±1
µA
20
µA
IOH = –50 µA
IOH = –2 mA
IOH = –6 mA
IOH = –12 mA
IOL = 50 µA
IOL = 2 mA
IOL = 6 mA
IOL = 12 mA
VIN = 5.5 V or GND
VIN = VCC or GND, IO = 0
Output leakage current IOFF
0
Input capacitance
CIN
3.3
—
—
5
µA VI or VO = 0 to 5.5 V
—
3.7
—
pF VI = VCC or GND
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating conditions.