14. Timers
Timer RD Start Register(1)
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
Address
After Reset
TRDSTR
0137h
11111100b
Bit Symbol
Bit Name
Function
RW
TRD0 count start flag(4)
0 : Count stops(2)
TSTART0
1 : Count starts
RW
TRD1 count start flag(5)
0 : Count stops(3)
TSTART1
1 : Count starts
RW
TRD0 count operation select bit 0 : Count stops at the compare match
CSEL0
w ith the TRDGRA0 register
1 : Count continues at the compare
RW
match w ith the TRDGRA0 register
TRD1 count operation select bit 0 : Count stops at the compare match
CSEL1
w ith the TRDGRA1 register
1 : Count continues at the compare
RW
match w ith the TRDGRA1 register
—
Nothing is assigned. If necessary, set to 0.
(b7 - b4) When read, the content is 1.
—
NOTES:
1. Set the TRDSTR register using the MOV instruction (do not use the bit handling instruction). Refer to 14.3.12.1
TRDSTR Register of Notes on Timer RD.
2. When the CSEL0 bit is set to 1, w rite 0 to the TSTART0 bit.
3. When the CSEL1 bit is set to 1, w rite 0 to the TSTART1 bit.
4. When the CSEL0 bit is set to 0 and generating the compare match signal(TRDIOA0), this bit is set to 0 (count stops).
5. When the CSEL1 bit is set to 0 and generating the compare match signal(TRDIOA1), this bit is set to 0 (count stops).
Figure 14.87 TRDSTR Register in Complementary PWM Mode
Rev.2.00 Aug 20, 2008 Page 235 of 501
REJ09B0251-0200