English
Language : 

PAS395 Datasheet, PDF (4/14 Pages) PULS GmbH – Charger for EDLC Capacitors (Ultra-Caps)
4
Performance Description
4.1
Input
Input Voltage:
Turn-on Voltage
Shut-down Voltage
Input Current:
Input Frequency:
Power Factor:
Inrush Current:
AC 220-240V -20%/+10% (176 to 264Vac)
typ. 164Vac
typ. 151Vac
typ. 5.2A (at 230Vac and 1000W output power)
50-60Hz ±6%
> 0.9
< 10A peak (active limited, temperature independent)
4.2
Output
End-of-Charge Voltage:
OVP voltage:
Output Current:
Adjustable:
360-460Vdc (output voltage)
Factory setting: 410Vdc
370-470Vdc; auto setting (OVP = Output over-voltage protection)
The OVP voltage automatically adjusts to 10V higher then the end-
of-charge voltage after following the procedure for setting the end-
of-charge voltage.
Testing the OVP level: Tune the end-of charge-voltage
potentiometer clockwise until the “Fully Charged” LED starts
flashing. This indicates the OVP level.
min. 2.5A at 400Vdc end-of-charge voltage
This document is proprietary. Any dispatch or disclosure of content is authorized only after written authorization by PULS GmbH.
All parameters are specified at 400V, 2.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
Specification: SP-PAS395 Rev: 3.1
Date: 2013/01/19
4-14