Figure 54. POL Group Configuration Window
9. Safety
The ZY7007 POL converters do not provide
isolation from input to output. The input devices
powering ZY7007 must provide relevant isolation
requirements according to all IEC60950 based
standards. Nevertheless, if the system using the
converter needs to receive safety agency approval,
certain rules must be followed in the design of the
system. In particular, all of the creepage and
clearance requirements of the end-use safety
requirements must be observed.
These
requirements are included in UL60950 - CSA60950-
00 and EN60950, although specific applications may
have other or additional requirements.
The ZY7007 POL converters have no internal fuse.
If required, the external fuse needs to be provided to
protect the converter from catastrophic failure. Refer
to the “Input Fuse Selection for DC/DC converters”
application note on www.power-one.com for proper
selection of the input fuse. Both input traces and the
ZD-00245 REV. 2.5
www.power-one.com
Page 31 of 35