TDA8941P Datasheet, PDF (6/21 Pages) NXP Semiconductors – 1.5 W mono Bridge Tied Load BTL audio amplifier | |||
|
◁ |
Philips Semiconductors
TDA8941P
1.5 W mono BTL audio ampliï¬er
8.5 Built-in protection circuits
The TDA8941P contains two types of protection circuits, i.e. short-circuit and thermal
shutdown.
8.5.1 Short-circuit protection
Short-circuit to ground or supply line â This is detected by a so-called âmissing
currentâ detection circuit which measures the current in the positive supply line and
the current in the ground line. A difference between both currents larger than 0.4 A,
switches the power stage to standby mode (high impedance).
Short-circuit across the load â This is detected by an absolute-current
measurement. An absolute-current larger than 2 A, switches the power stage to
standby mode (high impedance).
8.5.2 Thermal shutdown protection
The junction temperature is measured by a temperature sensor; at a junction
temperature of approximately 150 °C this detection circuit switches the power stage
to standby mode (high impedance).
9. Limiting values
Table 5: Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol Parameter
Conditions
Min
VCC
supply voltage
no signal
â0.3
operating
â0.3
VI
input voltage
â0.3
IORM
Tstg
Tamb
repetitive peak output current
-
storage temperature
non-operating
â55
operating ambient
â40
temperature
Ptot
total power dissipation
-
VCC(sc)
supply voltage to guarantee
-
short-circuit protection
Max
Unit
+25
V
+18
V
VCC + 0.3 V
2
A
+150
°C
+85
°C
1.25
W
12
V
10. Thermal characteristics
Table 6: Thermal characteristics
Symbol Parameter
Rth(j-a)
thermal resistance from junction to ambient
Conditions
in free air
Value Unit
100 K/W
9397 750 06864
Product speciï¬cation
Rev. 02 â 7 April 2000
© Philips Electronics N.V. 2000. All rights reserved.
6 of 21
|
▷ |