English
Language : 

LC79451KB Datasheet, PDF (9/38 Pages) ON Semiconductor – Controller and Driver
LC79451KB
2) HVON Flag hold time
Charge-pump starts with HVON Flag = 1.
In automatic charge-pump mode, charge-pump stops automatically after charge-pump rising period (set to control
register 1), and HVON Flag is automatically canceled (HVON Flag = 0.). HVON Flag is used for keeping the
charge-pump voltage.
In manual charge-pump mode, charge-pump is active until canceled of HVON Flag.
HVON Flag
tHD(1)
Fig.3. HVON Flag hold time
3) LE Flag hold time
The image data shift with LE Flag = 1.
When the data finish shifting, LE Flag is automatically canceled.
LE Flag
tHD(2)
Fig.4. LE Flag hold time
No.A2223-9/38