5-5. I2C (2-wire serial interface) Timing Characteristics
(Case without the special mention VDD = +2.5V, VSS = 0V, Ta = +25°C)
Parameter
Symbol
Conditions
min
typ
max
Unit
SCL frequency
fSCL(1)
-
-
400
kHz
Start condition setup time
tSU(5)
600
-
-
ns
Start condition hold time
tHD(3)
600
-
-
ns
SDA rise time
trDA(1)
-
-
300
ns
SDA fall time
tfDA(1)
-
-
300
ns
SCL rise time
trCL(1)
-
-
300
ns
SCL fall time
tfCL(1)
-
-
300
ns
SCL low pulse width
tPW(3)
1300
-
-
ns
SCL high pulse width
tPW(2)
600
-
-
ns
Data setup time
tSU(6)
100
-
-
ns
Data hold time
tHD(4)
0
-
900
ns
Stop condition setup time
tSU(7)
600
-
-
ns
STOP - START bus open time tBUF
1300
-
-
ns
1) I2C interface bus timing
START condition
tfCL(1)
trCL(1)
(90%)
SCL
(10%)
tSU(5)
tPW(2)
tHD(3)
tPW(3)
tSU(6)
(90%)
SDA
(10%)
STOP condition
tSU(7)
tfDA(1) trDA(1) tHD(4)
Acknowledge (ACK)
tBUF
Fig.5. I2C bus timing
2) Timing of BUSY and START Flag after setting START command in I2C interface
Output of BUSY means START Flag. During in BUSY = 1, “WAVEFORM PARAMETER” and “CONTROL
REGISTER” are write inhibit state. An internal state is charge-pump rising period before the waveform output or
during the waveform output. After outputs waveform from segment, BUSY and START Flag are automatically
canceled. (Cf. 6-3)
(ACK)
SCL
BUSY
START Flag
*2
*1
*1 Automatic charge-pump mode : charge-pump rising period (set to control register 1) + waveform
output period (set to waveform parameter)
Manual charge-pump mode : waveform output period (set to waveform parameter)
*2 BUSY and START Flag are automatically canceled.
Fig.6. I2C BUSY output, and START Flag timing
No.A2223-10/38