11. Resistance to electrical and electromagnetic disturbances
11.1. Electrostatic discharges
See. § 1.1 Absolute Maximum Ratings
11.2. Schäffner pulses
Shäffner pulses are applied to the power supply wires of the equipment implementing the AMIS-30622 (see
application schematic), according to Renault 36-00-808/--E document.
Pulse
#1
#2a
#3a
#3b
#5b (load dump)
amplitude
-100V
+100V
-150V (from +13.5V)
+100V (from +13.5V)
+21.5V (from +13.5V)
rise time
≤ 1µs
≤ 1µs
5ns
5ns
≤ 10ms
pulse duration
2ms
50µs
100ns (burst)
100ns (burst)
400ms
Rs
10Ω
2Ω
50Ω
50Ω
≤ 1Ω
operating class
C
B
A
A
C
11.3. EMC
Bulk current injection (BCI), according to Renault 36-00-808/--E document (p61).
current
60mA
100mA
200mA
operating class
A
B
C
11.4. EMI
EMI requirement is given here as a target, since it is also PCB dependent. Any EMI issue will have to be solved
on common basis with the customer.
Radiated disturbance electromagnetic quietness test, according to Renault 36-00-808/--E document:
• Permanent broadband limit (Renault 36-00-808/--E document diagram p98)
• Narrow band limit (Renault 36-00-808/--E document diagram p99)
11.5. Power supply micro-interruptions
According to Renault 36-00-808/--E (p47 and followings).
test
10µs micro-interruptions (1)
100µs micro-interruptions
5ms micro-interruptions
50ms micro-interruptions
300ms micro-interruptions
operating class
A
B
B
C
C
Note 1: To achieve Class A a 100nF capacitor between Vbat and ground is needed in case HW is connected to
Vbat. (see § 7 typical application)
Rev. 3 | Page 41 of 42 | www.onsemi.com