English
Language : 

CAT5409WI-25 Datasheet, PDF (4/16 Pages) ON Semiconductor – Quad Digitally Programmable Potentiometers with 64 Taps and I²C Interface
CAT5409
D.C. OPERATING CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol
ICC
ISB
ILI
ILO
VIL
VIH
VOL1
Parameter
Power Supply Current
Standby Current (VCC = 5.0V)
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage (VCC = 3.0V)
Test Conditions
fSCL = 400kHz
VIN = GND or VCC, SDA Open
VIN = GND to VCC
VOUT = GND to VCC
IOL = 3 mA
Min
-1
VCC x 0.7
CAPACITANCE (1)
TA = 25ºC, f = 1.0MHz, VCC = 5V
Symbol Test
CI/O Input/Output Capacitance (SDA)
CIN Input Capacitance (A0, A1, A2, A3, SCL, ¯W¯P¯)
Conditions
VI/O = 0V
VIN = 0V
Max
1
1
10
10
VCC x 0.3
VCC + 1.0
0.4
Max.
8
6
Units
mA
µA
µA
µA
V
V
V
Units
pF
pF
A.C. CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol
fSCL
TI(1)
tAA
tBUF(1)
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR(1)
tF(1)
tSU:STO
tDH
Parameter
Clock Frequency
Noise Suppression Time Constant at SCL, SDA Inputs
SLC Low to SDA Data Out and ACK Out
Time the bus must be free before a new transmission can
start
Start Condition Hold Time
Clock Low Period
Clock High Period
Start Condition SetupTime (for a Repeated Start Condition)
Data in Hold Time
Data in Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
POWER UP TIMING (1)
Symbol
tPUR
tPUW
Parameter
Power-up to Read Operation
Power-up to Write Operation
Min
Typ Max Units
400 kHz
50
ns
0.9
µs
1.2
µs
0.6
µs
1.2
µs
0.6
µs
0.6
µs
0
ns
100
ns
0.3
µs
300
ns
0.6
µs
50
ns
Max Units
1
ms
1
ms
Note:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
Doc. No. MD-2010 Rev. L
4
© 2008 SCILLC. All rights reserved.
Characteristics subject to change without notice