INSTRUCTION FORMAT (continued)
Global Transfer Data Register (DR) to Wiper Control Register (WCR)
S
DEVICE ADDRESSES
A
INSTRUCTION
T 0 1 0 1 A3 A2 A1 A0 C 0 0 0 1 R1 R0 0 0
A
K
R
T
AS
CT
KO
P
Global Transfer Wiper Control Register (WCR) to Data Register (DR)
S
DEVICE ADDRESSES
A
INSTRUCTION
T 0 1 0 1 A3 A2 A1 A0 C 1 0 0 0 R1 R0 0 0
A
K
R
T
AS
CT
KO
P
Transfer Wiper Control Register (WCR) to Data Register (DR)
S
DEVICE ADDRESSES
A
INSTRUCTION
AS
T 0 1 0 1 A3 A2 A1 A0 C 1 1 1 0 R1 R0 P1 P0 C T
A
K
KO
R
P
T
Transfer Data Register (DR) to Wiper Control Register (WCR)
S
DEVICE ADDRESSES
A
INSTRUCTION
AS
T 0 1 0 1 A3 A2 A1 A0 C 1 1 0 1 R1 R0 P1 P0 C T
A
K
KO
R
P
T
Increment (I)/Decrement (D) Wiper Control Register (WCR)
S
DEVICE ADDRESSES
A
INSTRUCTION
A
DATA
S
T 0 1 0 1 A3 A2 A1 A0 C 0 0 1 0 0 0 P1 P0 C I/D I/D . . . I/D I/D T
A
K
K
O
R
P
T
Note:
(1) Any write or transfer to the Non-volatile Data Registers is followed by a high voltage cycle after a STOP has been issued.