AMIS-30585 Datasheet, PDF (15/17 Pages) AMI SEMICONDUCTOR – S-FSK PLC Modem | |||
|
◁ |
AMISâ30585
Absolute Maximum Ratings and Storage Conditions
Absolute Maximum Ratings
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 23. POWER SUPPLY PINS VDD, VDDA, VSS, VSSA
Parameter
Description
Condition
Min.
Max.
Unit
VDDABXM
Absolute maximum digital power supply
VSSâ0.3
3.9
V
VDDAABSM
Absolute maximum analog power supply
VSSAâ0.3
3.9
V
VDDâVDDAABSM Absolute maximum difference between digital and
analog power supply
â0.3
0.3
V
VSSâVSSAABSM Absolute maximum difference between digital and
analog ground
â0.3
0.3
V
Table 24. NON 5 V SAFE PINS: TX_OUT, ALC_IN, RX_IN, RX_OUT, REF_OUT, M50HZ_IN, XIN, XOUT, TDO, TDI,
TCK, TMS, TRSTB, TEST
Parameter
Description
Condition
Min.
Max.
Unit
VINABSM
Absolute maximum input for normal digital inputs and
analog inputs
VSS*â0.3 VDD*+0.3
V
VOUTABSM
Absolute maximum voltage at any output pin
VSS*â0.3 VDD*+0.3
V
Table 25. 5 V SAFE PINS: TX_ENB, TXD, RXD, BR0, BR1, IO0, IO2, RESB
Parameter
Description
Condition
V5VSABSM
Absolute maximum input for digital 5 V safe inputs
VOUT5VABSM
Absolute maximum voltage at 5 V safe output pin
Min.
VSSâ0.3
VSSâ0.3
Max.
Unit
6.0
V
3.9
V
Marking and Delivery
Delivery of the production devices will be in:
⢠Tubes
Y
⢠Trays
N
⢠Tape on Reel N
Marking
Bottom marking:
⢠AAAA Four letter code for country of assembly
Top marking:
⢠Logo
AMIS logo
⢠XXXXYZZ Date code (XXXX),
plant identifier (Y), traceability code
⢠Text
ARM
⢠CUST.PART.NR AMIS30585AGA
⢠MMMMâMM C585âNAD
Storage Conditions
Storage conditions for packaged components before
mounting for a maximum storage period of one year:
For through hole devices:
⢠Maximum temperature 40°C and maximum relative
humidity 90 percent
For surface mount devices in dry bag:
⢠Maximum temperature 40°C and maximum relative
humidity 90 percent
For surface mount devices not in dry bag:
⢠Maximum temperature 30°C and maximum relative
humidity 60 percent (moisture sensitivity level two
according to IPC/JEDEC standard JâSTDâ020A)
In case the storage conditions for surface mount devices
are exceeded, a baking operation has to be performed before
the devices can be mounted.
In case of dry bag delivery the storage details are
summarized on a label attached to each dry bag.
The absolute maximum temperature ratings for storage of
limited duration are â55°C and 150°C.
http://onsemi.com